CompoBus/S Communication Unit Part Names and Functions
Section 3-2
3-2
CompoBus/S Communication Unit Part Names and
Functions
Note
1.
Do not turn ON the power to the Communication Unit when the Mobile
Console is connected. Communications will not be established with the
Sensors if the Mobile Console is already connected when the Unit power
is turned ON.
2.
Always set the Sensors to RUN mode when using the Fiber Amplifier Sen-
sor Communication Unit for CompoBus/S.
3.
A Sensor communications error will occur under the following conditions
after the Mobile Console is connected with it’s power turned ON.
• When the power to the Mobile Console is turned OFF.
• When the Mobile Console is left idle while connected, causing the
power to automatically turn OFF.
• When the Mobile Console battery goes low, causing the power to turn
OFF.
Do not allow the above conditions to occur when using the Mobile Console,
or use the Mobile Console when problems will not occur even if a Sensor
communications error occurs.
Indicators
The following table shows the operation of the indicators
ERR
COMM
PWR
SS
U.ERR
1 2 3 4
ON
1 3
5
7
9
11
13
15
0 2
4
6
8
A
C
E
NODE
ADR
Communications Connector
Connector for CompoBus/S communications.
Power is supplied to all Sensors connected to
the Communication Unit through the
CompoBus/S communications power supply
terminals.
Power Supply Connector
The E3X-SRT21 is supplied power from the Communications
Connector, so there is no power supply cable.
Indicators
Sensor Reset Switch
Resets Sensors connected to the Unit by turning Sensor
power OFF and ON again.
Rotary switches
E3X-MC11 Mobile Console Connector
Used to connect the Mobile Console.
DIP switch
Indicator
Name
Color
Display
Meaning
PWR
Power
Green
Lit
Communications power supply is ON.
Not lit
Communications power supply is OFF.
COMM
Communi-
cating
Yellow
Lit
CompoBus/S communications are nor-
mal.
Not lit
A CompoBus/S communications error
has occurred or communications are on
standby.
ERR
Communi-
cations
error
Red
Lit
A CompoBus/S communications error
has occurred.
Not lit
CompoBus/S communications are nor-
mal or communications are on standby.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...