Explicit Message Communications
Section 2-6
4.
Set the response monitoring time to 6,000 ms minimum using the
CMND(490) instruction to send an explicit message.
Using C200HW-DRM21 or CVM1-DRM21
Set the response monitoring time to 6,000 ms using the IOWR(223) instruc-
tion to send an explicit message. (The message monitoring timer does not
need to be set with the DeviceNet Configurator.)
2-6-2
READ Command
The READ command is used to read data from the Fiber Amplifier Sensor
Communication Unit or the Sensors connected to it. When an OMRON mas-
ter is used, the formats of the command and response blocks are as follows:
Command Block
Response Block
Normal Format
Note The bytes of read data for Batch Read Incident Light Levels and Batch Read
Threshold Settings is twice the number of Sensors being read. The number of
received bytes is two plus twice the number of Sensors being read.
Error Format
List of READ
Commands
The following table lists the explicit message READ commands.
Destination
node
address
1 byte
1 byte
2 bytes
2 bytes
1 byte
Service
Code
Class ID
Instance ID
Attribute ID
0E fixed
No. of received bytes
Destination
node
address
8E fixed
Service Code
Read data
2 bytes (See note.)
1 byte
1 byte
2 bytes
0004 (See note.)
No. of received bytes
Destination
node
address
Service Code
Error Code
94 fixed
0004
2 bytes
1 byte
1 byte
2 bytes
Explicit message
Function
Command
Class
ID
Instance
ID
Attribute
ID
Read ON/OFF Data
Reads the ON/OFF status of
connected Sensors
009C
0000
01
Read Status
Reads the status of the
Fiber Amplifier Sensor Com-
munication Unit
009C
0000
02
Read Incident Light
Level
Specifies the unit number as
the instance ID and reads
the incident light level.
009C
Unit
number
03
Batch Read Incident
Light Levels
Reads incident light levels of
connected Sensors in a
batch.
009C
0000
67
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...