17
DeviceNet Communication Unit Part Names and Functions
Section 2-2
2-2
DeviceNet Communication Unit Part Names and Functions
Note
1.
Do not turn ON the power to the Communication Unit when the Mobile
Console is connected. Communications will not be established with the
Sensors if the Mobile Console is already connected when the Unit power
is turned ON.
2.
Always set the Sensors to RUN mode when using the Fiber Amplifier Sen-
sor Communication Unit for DeviceNet. When other modes (SET or ADJ)
are set, the Fiber Amplifier Sensor Communication Unit cannot read or
write Sensor data.
3.
A Sensor communications error will occur under the following conditions
after the Mobile Console is connected with it’s power turned ON.
• When the power to the Mobile Console is turned OFF.
• When the Mobile Console is left idle while connected, causing the
power to automatically turn OFF.
• When the Mobile Console battery goes low, causing the power to turn
OFF.
Do not allow the above conditions to occur when using the Mobile Console,
or use the Mobile Console when problems will not occur even if a Sensor
communications error occurs.
Indicators
The following table shows the operation of the indicators.
NS
MS
SS
1 2 3 4
ON
0
1 3
5
7
9
11
13
15
1
2
3
4
5
6
7
8
9
0 1
2
3
4
5
6
7
8
9
NODE
ADR
DIP switch
E3X-MC11 Mobile Console Connector
Used to connect the Mobile Console.
When the Mobile Console is
connected, incident light level
monitoring and explicit message
communications are disabled.
Communications Connector
Connector for DeviceNet communications.
Power Supply Connector
The E3X-DRT21 is supplied power from the Communications
Connector, so there is no power supply cable.
Indicators
Sensor Reset Switch
Resets Sensors connected to the Unit by turning Sensor
power OFF and ON again.
Rotary switches
Indicator
Name
Color
Status
Meaning
MS
Module
status
Green
Lit
Operating normally.
Flashing Not set.
Red
Lit
A fatal error has occurred.
Flashing A non-fatal error has occurred.
---
Not lit
The power is OFF.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...