99
Mounting
Section 5-1
Applicable Slave Connectors (Yes: Can be used; No: Cannot be used)
Always use the Slave Connectors specified in the above table. Do not use
the Slave Connectors listed as not being applicable.
4.
Connect the Fiber Amplifier Units to each other only after mounting the
Units to the DIN Track.
5-1-1
Mounting Procedure
Use the following procedure to mount the Fiber Amplifier Sensor Communica-
tion Unit.
1,2,3...
1.
Hook the top of the Unit onto the DIN Track.
2.
Push the bottom of the Unit onto the DIN Track.
Fiber Amplifier Sensor
Communication Unit
Slave Connector for Fiber Amplifier Unit
Cordless
Cord with
1 wire
Cord with
2 wires
E3X-CN02
E3X-CN12
E3X-CN22
E3X-DRT21 (DeviceNet)
Yes
No
No
E3X-SRT21 (CompoBus/S) Yes
No
No
E3X-CIF11 (RS-422)
Yes
Yes
No
DeviceNet or CompoBus/S
Communication Units
RS-422 Communication Unit
Fiber Amplifier Unit
E3X-CN02
only
Plug in
here
Fiber Amplifier Unit
E3X-CN12
E3X-CN02
or
Plug in
here
DIN Track
Fiber Amplifier Sensor Communication Unit
Push in direction of
arrows.
Содержание E3X-CIF11
Страница 3: ...iv...
Страница 21: ...10 Connecting Fiber Amplifier Units Section 1 3...
Страница 63: ...52 Setting Monitoring and Operating Sensors from the DeviceNet Configurator Section 2 7...
Страница 107: ...96 CompoWay F Message Communications Section 4 5...
Страница 125: ...114 Monitoring Incident Light Levels of E3X DA6 P Sensors Appendix B...
Страница 133: ...122 DeviceNet Connection Settings Appendix C...
Страница 135: ...124 DeviceNet Device Profile Appendix D...
Страница 137: ...126 Revision History...