background image

Miniature Limit Switch

 

D4CC

1

Miniature Limit Switch

D4CC

Many Models Including Roller Lever 
Switches are Only 16-mm Thick with 
Connector

• New center roller lever models that enable ganged mounting of 

up to 6 Switches.

• Cable connectors for easy Switch replacement.

• Triple-seal construction for plungers to provide IEC IP67, UL, 

and CSA (type 3, 4, 13) degree of protection.

• Operation indicators available for easy monitoring (standard in-

dicator is lit when Switch is not operating).

Model Number Structure

Model Number Legend

1. Rated Load

(These codes are different from suffix codes of the D4C)

1:

1 A at 125 VAC

2:

1 A at 125 VAC (with LED indicator)

3:

1 A at 30 VDC

4:

1 A at 30 VDC (with LED indicator)

2. Actuator

01:

Pin plunger

02:

Roller plunger

03:

Crossroller plunger

10:

Bevel plunger

24:

Roller lever

31:

Sealed pin plunger

32:

Sealed roller plunger

33:

Sealed crossroller plunger

41:

Panel mount pin plunger

42:

Panel mount roller plunger

43:

Panel mount crossroller plunger

50:

Plastic rod

60:

Center roller lever

Note: With standard models, the operation indicator turns OFF when

the switch operates. If models with operation indicators that
turn ON when the switch operates are required, add "-B” to the
end of the model number.

1        2

D4CC-

@

0

@@

Содержание D4CC -

Страница 1: ...Legend 1 Rated Load These codes are different from suffix codes of the D4C 1 1 A at 125 VAC 2 1 A at 125 VAC with LED indicator 3 1 A at 30 VDC 4 1 A at 30 VDC with LED indicator 2 Actuator 01 Pin pl...

Страница 2: ...3024 D4CC 4024 D4CC 1031 D4CC 2031 D4CC 3031 D4CC 4031 D4CC 1032 D4CC 2032 D4CC 3032 D4CC 4032 D4CC 1033 D4CC 3033 D4CC 4033 D4CC 1041 D4CC 2041 D4CC 3041 D4CC 4041 D4CC 1042 D4CC 2042 D4CC 3042 D4CC...

Страница 3: ...f 0 4 min AC and a time constant of 7 ms max DC 3 Lamp loads have an inrush current of 10 times the steady state current 4 Motor loads have an inrush current of 6 times the steady state current D4CC 3...

Страница 4: ...nd and between each terminal and non current carrying metal part Vibration resistance Malfunction 10 to 55 Hz 1 5 mm double amplitude see note 3 Shock resistance Destruction 1 000 m s2 min Malfunction...

Страница 5: ...he free position the indicator is lit and when the actuator is turned or pushed and the contact comes into contact with the NO side the indicator turns OFF Plugs NC COM E NO NO COM NC E 2 3 1 4 NO COM...

Страница 6: ...ller Center lever Built in switch Ground terminal Molded resin O ring NBR Nitrile rubber diaphragm Open space to reduce a change in internal pneumatic pressure and to prevent the res piratory movement...

Страница 7: ...ax 57 max 40 max Indicator 50 max 65 max 10 dia stainless steel plunger Indicator 40 max 59 5 max 75 max 12 dia x 5 stainless steel roller 40 max 16 Indicator 75 max 59 5 max 40 max 12 dia x 5 stainle...

Страница 8: ...x 5 stainless steel roller Rubber seal Indicator 57 max 40 max 12 dia x 5 stainless steel roller Rubber seal Indicator 40 max 57 max Sealed Roller Plunger D4CC 032 Sealed Crossroller Plunger D4CC 033...

Страница 9: ...0 7 max Indicator Center Roller Lever D4CC 60 17 5 dia x 7 stainless steel roller 0 Two 5 1 0 2 dia holes counter sunk 10 2 dia depth 6 1 m 2 m 5 m 10 m Model Cable length L XS2F D421 C A XS2F D421 D...

Страница 10: ...2 30 0 2 58 7 0 2 25 0 2 5 1 0 2 11 dia D4C P002 For D4CC 002 D4C P020 For D4CC 024 44 OP of WLD2 Two M5 x 0 8 tapped hole See note 3 Note 1 Four hexagonal flat head bolts M5 x 0 8 length 10 and two A...

Страница 11: ...ection re tight en to the torque specified above Be careful not to allow any for eign substance to enter the Switch Plug Tightening Connect the plug connector B to the connector threads of the D4CC Th...

Страница 12: ...r roller lever along with the dog or cam so that the concave part A of the head is located between the convex parts of the head as shown below when the center roller lever is pressed by the dog or cam...

Отзывы: