manualshive.com logo in svg
background image

General-purpose Limit Switch

 

D4A-

@N

F-9

Limit 

Switches

General-purpose Limit Switch

D4A-

@N

The Limit Switch with Better Seal, Shock 
Resistance, and Strength

• A double seal on the head, a complete gasket cover, and other 

features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 
13).

• Block mounting method to reduce weight to 290 g.

• Block mounting method also reduces downtime for mainte-

nance.

• Wide standard operating temperature range: 

–40

°

C to 100

°

C (standard type).

• Models with fluoro-rubber available for greater resistance to 

chemicals.

• DPDT, double-break models available for complex operations.

Model Number Structure

Model Number Legend

1. Receptacle Box

1:

1/2-14 NPT conduit (SPDT, double-break)

2:

1/2-14 NPT conduit (DPDT, double-break)

3:

G 1/2 conduit (SPDT, double-break)

4:

G 1/2 conduit (DPDT, double-break)

5:

M20 x 1.5 conduit (SPDT, double-break)

6:

M20 x 1.5 conduit (DPDT, double-break)

2. Switch Box

1:

SPDT, double-break, without indicator

3:

SPDT, double-break, neon lamp

A:

SPDT, double-break, LED (12 VDC)

C:

SPDT, double-break, LED 
(24 VDC, leakage current: 4 mA)

E:

SPDT, double-break, LED 
(24 VDC, leakage current: 1.3 mA)

G:

SPDT, double-break, LED (48 VDC)

5:

DPDT, double-break, simultaneous operation, without indi-
cator

7:

DPDT, double-break, sequential operation, without indicator
(See note 1.)

9:

DPDT, double-break, center neutral operation, without indi-
cator (See note 2.)

L:

DPDT, double-break, simultaneous operation, neon lamp

M:

DPDT, double-break, sequential operation, neon lamp
(See note 1.)

N:

DPDT, double-break, center neutral operation, neon lamp
(See note 2.)

P:

DPDT, double-break, simultaneous operation, LED

Q:

DPDT, double-break, sequential operation, LED 
(See note 1.)

R:

DPDT, double-break, center neutral operation, LED
(See note 2.)

3. Head

01:

Roller lever, standard

02:

Roller lever, high-sensitivity

03:

Roller lever, low torque

04:

Roller lever, high-sensitivity, low torque

05:

Roller lever, maintained

17:

Roller lever, sequential operation

18:

Roller lever, center neutral operation

06:

Side plunger, standard

07-V: Side plunger, vertical roller
07-H: Side plunger, horizontal roller
08:

Side plunger, adjustable

09:

Top plunger, standard

10:

Top plunger, roller

11:

Top plunger, adjustable

12:

Flexible rod, spring wire

14:

Flexible rod, plastic rod

15:

Flexible rod, cat whisker

16:

Flexible rod, coil spring

Note: 1.

Use the D4A-0017N Special Head.

2.

Use the D4A-0018N Special Head.

3.

Fluoro-rubber sealed type is also available.

1  2     3

D4A-

@@@@

N

Содержание D4A-1101N

Страница 1: ...rrent 1 3 mA G SPDT double break LED 48 VDC 5 DPDT double break simultaneous operation without indi cator 7 DPDT double break sequential operation without indicator See note 1 9 DPDT double break center neutral operation without indi cator See note 2 L DPDT double break simultaneous operation neon lamp M DPDT double break sequential operation neon lamp See note 1 N DPDT double break center neutral...

Страница 2: ...A 1303N UL CSA D4A 1A03N D4A 1C03N D4A 1E03N D4A 1G03N D4A 1104N UL CSA D4A 1304N UL CSA D4A 1A04N D4A 1C04N D4A 1E04N D4A 1G04N D4A 1105N UL CSA D4A 1305N UL CSA D4A 1A05N D4A 1C05N D4A 1E05N D4A 1G05N D4A 1106N UL CSA D4A 1306N UL CSA D4A 1A06N D4A 1C06N D4A 1E06N D4A 1G06N D4A 1107 VN UL CSA D4A 1307 VN UL CSA D4A 1A07 VN D4A 1C07 VN D4A 1E07 VN D4A 1G07 VN D4A 1107 HN UL CSA D4A 1307 HN UL CSA...

Страница 3: ...D4A 2L03N D4A 2P03N D4A 2504N UL CSA D4A 2L04N D4A 2P04N D4A 2505N UL CSA D4A 2L05N D4A 2P05N D4A 2717N UL CSA D4A 2M17N D4A 2Q17N D4A 2918N UL CSA D4A 2N18N D4A 2R18N D4A 2506N UL CSA D4A 2L06N D4A 2P06N D4A 2507 VN UL CSA D4A 2L07 VN D4A 2P07 VN D4A 2507 HN UL CSA D4A 2L07 HN D4A 2P07 HN D4A 2508N UL CSA D4A 2L08N D4A 2P08N D4A 2509N UL CSA D4A 2L09N D4A 2P09N D4A 2510N UL CSA D4A 2L10N D4A 2P10...

Страница 4: ...0 and 21 Type Appearance 1 2 14NPT conduit See note 2 G1 2 conduit See note 1 M20 x 1 5 See note 1 Model Approved standards Model Approved standards Model Approved standards SPDT double break D4A 1000N UL CSA D4A 3000N UL CSA D4A 5000N UL CSA DPDT double break D4A 2000N UL CSA D4A 4000N UL CSA D4A 6000N UL CSA Type Appearance Without indicator With neon lamp indicator AC With LED indicator DC Mode...

Страница 5: ... Appearance Approved standards Roller lever See note 1 UL CSA UL CSA Side plunger UL CSA Top plunger UL CSA Flexible rod UL CSA Standard D4A 0001N High sensitivity D4A 0002N Low torque D4A 0003N see note 2 High sensitivity low torque D4A 0004N see note 2 Sequential operation D4A 0017N see note 3 Center neutral operation D4A 0018N see note 3 Maintained D4A 0005N Standard D4A 0006N Horizontal roller...

Страница 6: ...tral Operation Agency Standard File No UL UL508 E76675 CSA CSA C22 2 No 14 LR45746 Rated voltage Carry current Current Volt amperes Make Break Make Break 120 VAC 240 VAC 480 VAC 600 VAC 10 A 60 A 30 A 15 A 12 A 6 A 3 A 1 5 A 1 2 A 7 200 VA 720 VA Rated voltage Carry current Current Volt amperes Make Break Make Break 120 VAC 240 VAC 10 A 60 A 30 A 6 A 3 A 7 200 VA 720 VA Rated voltage Carry current...

Страница 7: ...See note 5 0 8 A 0 2 A 0 2 A 0 8 A 0 2 A 250 VDC See note 5 0 4 A 0 1 A 0 1 A 0 4 A 0 1 A DPDT double break without indicator 125 VAC 5 A 2 A 4 A 3 A 250 VAC 3 A 1 A 2 A 1 5 A 480 VAC 1 5 A 0 5 A 1 A 0 8 A 600 VAC 1 A 0 4 A 0 7 A 0 5 A 14 VDC 5 A 2 A 4 A 3 A 30 VDC 3 A 1 A 2 A 1 5 A 125 VDC 0 4 A 0 1 A 0 4 A 0 1 A 250 VDC 0 2 A 0 05 A 0 2 A 0 05 A DPDT double break with indicator 125 VAC 5 A 2 A 4...

Страница 8: ...el Operating frequency Mechanical 300 operations minute Electrical 30 operations minute Rated frequency 50 60 Hz Insulation resistance 100 MΩ min at 500 VDC between terminals of the same polarity between current carrying metal parts and ground and between each terminal and non current carrying metal part Contact resistance 25 mΩ max initial value Temperature rise 50 C max Dielectric strength 1 000...

Страница 9: ...4A 1 07 HN D4A 1 07 VN D4A 1 08N D4A 2 06N D4A 2 07 HN D4A 2 07 VN D4A 2 08N OF max 19 61 N 19 61 N 19 61 N 19 61 N 19 61 N 19 61 N 19 61 N 19 61 N RF min 4 90 N 4 90 N 4 90 N 4 90 N 4 90 N 4 90 N 4 90 N 4 90 N PT max 2 4 mm 2 4 mm 2 4 mm 2 4 mm 2 4 mm 2 4 mm 2 4 mm 2 4 mm OT min 5 1 mm 5 1 mm 5 1 mm 5 1 mm 5 1 mm 5 1 mm 5 1 mm 5 1 mm MD max 0 6 mm 0 6 mm 0 6 mm 0 6 mm 1 0 mm 1 0 mm 1 0 mm 1 0 mm ...

Страница 10: ... Internal circuit NO ON NC ON Lamp unit Lamp unit 4 NO 1 NC 3 NO 2 NC D4A 0A00N D4A 0C00N D4A 0E00N D4A 0G00N Type Simultaneous operation Sequential operation Center neutral operation Internal circuit of indicator Without indicator With neon lamp indicator See note 3 With LED indicator See note 3 4 1 8 5 3 2 7 6 D4A 0500N 4 1 8 5 3 2 7 6 D4A 0700N See note 1 4 1 8 5 3 2 7 6 D4A 0900N See note 2 4 ...

Страница 11: ...erates on CW and pole 2 operates CCW Free position FP Operating Pole 1 operates first Pole 2 operates second D4A center neutral type Pole1 Pole2 Pole1 Pole2 This head is compatible with a SPDT type head Free position FP Pole 1 and pole 2 are actuated simultaneously Operates either CW CCW or both Pole 2 operates on CCW Free position FP Pole 1 operates on CW Note The contact configuration of the cen...

Страница 12: ...ions or more with the 2 pole Double break Switches and 30 million mechanical operations or more with the DPDT Double break Switches Ground Terminal Screw A ground terminal is provided to enhance safety Switch Box Screw Sealed Gasket With the Roller Lever and Side Plunger Switches the direction of the switch head can be varied to any of the four directions by loosing the roller lever switch screws ...

Страница 13: ...aintained Sequen tial Operating Center Neutral Operating Switches Operating Part Rear of Head Procedures 1 Dismount the head by loosening the four screws that secure it 2 Turn over the head to set the desired operation CW CCW or both The desired side can be selected by setting the mode selector knob shown in the figure This knob is factory set to the CW CCW both way operation position 3 When set t...

Страница 14: ...rom the head The operating head can be positioned and locked in any of four 90 positions The lever can lock in any position through 360 around the shaft The lever can be reversed and attached to the shaft in which case the switching operation should com plete in a range of 0 to 180 By loosening the Allen head bolt on an adjustable roller lever or rod lever the length of the lever can be adjusted D...

Страница 15: ...he lamp section to the right do not push strongly Remove the lamp section Mount the lamp section so that legend NC ON or NO ON will appear in the display window Note In either case the lamp will not light when the load is ON 86 9 to 92 4 73 to 78 5 38 9 to 44 4 67 to 72 5 44 9 to 50 4 59 to 64 5 52 9 to 58 4 D4A A00 D4A A10 D4A A20 D4A A30 25 to 30 5 The type of switch box is printed The type is a...

Страница 16: ... 48 21 16 5 44 75 5 2 6R 2 6R 29 4 0 2 59 5 0 2 28 29 5 29 5 7 25 dia 7 25 dia Standard D4A 1 01N D4A 2 01N High sensitivity D4A 1 02N D4A 2 02N Center Neutral Operating D4A 2 18N Low Torque D4A 1 03N D4A 2 03N High sensitivity Low Torque D4A 1 04N D4A 2 04N Sequential Operation D4A 2 17N Maintained D4A 1 05N D4A 2 05N Four M4 length 12 screws for head 0 5 2 0 2 dia mounting holes Two M5 length 20...

Страница 17: ...8N Four M4 length 12 screws for head Stainless steel plunger 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth 10 screws for back mounting Four M4 length 12 screws for head 11 dia x 5 stainless steel roller 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth 10 screws for back mounting Four M4 lengt...

Страница 18: ... 10 dia Standard D4A 1 09N D4A 2 09N Roller Plunger D4A 1 10N D4A 2 10N Adjustable D4A 1 11N D4A 2 11N Four M4 length 12 screws for head 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth 10 screws for back mounting Four M4 length 12 screws for head 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth...

Страница 19: ...rom any direction except the axial direction i e from the top 2 The optimum operating range of the stainless rod is within 1 3 of the entire length from the top end Spring Wire D4A 1 12N D4A 2 12N Plastic Rod D4A 1 14N D4A 2 14N Cat Whisker D4A 1 15N D4A 2 15N Four M4 length 12 screws for head 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth 10 s...

Страница 20: ...m operating range of the stainless rod is within 1 3 of the entire length from the top end Coil Spring D4A 1 16N D4A 2 16N Four M4 length 12 screws for head 0 5 2 0 2 dia mounting holes Two M5 length 20 screws for box 1 2 14NPT conduit Two No 10 32UNF depth 10 screws for back mounting 7 9 38 1 18 39 4 7 9 38 1 18 9 16 5 19 5 38 1 18 9 7 9 11 5 7 9 38 1 18 9 21 15 33 7 18 9 9 M5 Allen bolt 19 1 dia...

Страница 21: ... Lever D4A D00 Fork Lever Lock D4A E30 Fork Lever Lock D4A E20 33 to 91 adjusta ble Stainless sintered roller 150 max adjusta ble Stainless sintered roller Stainless sintered roller Stainless sintered roller Stainless sintered roller See note See note 90 38 1 2 3 6 7 9 9 6 2 38 1 26 22 26 38 1 2 3 6 7 9 9 90 22 6 2 38 1 M5 Allen bolt 19 1 dia 7 3 dia M5 Allen bolt 19 1 dia 7 3 dia Fork Lever Lock ...

Страница 22: ...model Contact the manufacturer of the equipment for any maintenance or repairs required Tightening Torque A loose screw may cause malfunctions Be sure to tighten each screw to the proper tightening torque as shown in the table Note When using M5 Allen head bolts particularly when the head di rection has been changed check the torque of each screw and make sure that the screws are free of foreign s...

Отзывы: