5.
Writing data to CS
Transfer the converted and modified programs, PLC settings and data memory to CS-series CPU Unit.
Required items
Support software
(PC)
CX-One
CXONE-AL[][]C-V[]/ AL[][]D-V[]
(CX-Programmer)
Connecting
cable
CS1W-CN226/626 + CS1W-CIF31
CS1
CS1D
PC
CX-Programmer
Connecting cable
CS1W-CN226/626
CS1W-CIF31
Peripheral port
(1) Connect the CS1 CPU Unit and the PC.
(2) Start up the CX-Programmer, and open the program file for
CS
that you converted or changed.
(3) Connect the CS and CX-Programmer online.
(4) Transfer the ladder program. (Select
PLC - Transfer – To PLC
.) Select the checkbox for
Program
. Press the
OK
Button to start transfer.