75
System Parameters
Section 4-2
• A period of time set here is waited for after the power to the MC Unit has
been turned ON, and then starts communications with the slaves.
Explanation
• Set 1 to 32 zone bits.
• In Pn0012, set the leading address for the zone data (upper and lower
limits) for which the zone bits are to be used.
• If 0 is set for Pn00011, zone bits will not be used.
• For details on zone bit operations, refer to
Explanation
• Set the leading address for the zone data for the zone bits that are to be
used.
Note
Zone data is made of long words (32 bits).
Example: With two zone bits (P00011 = 2), make the following settings to set
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00011
500Ah
Number of zone bits
Data
---
No
Data configuration
Setting range
00000000 to 00000020 Hex
(0 to 32)
Initial value
00000000 (0)
31
00
Number of zone bits
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00012
500Bh
Zone data leading address
Data
---
No
Data configuration
Initial value
00000000 (0)
31
00
Variable type
16 15
Address
Bits
Function and explanation
00 to 15
Address
Sets the leading address for the specified variable.
Refer to the variable type for the address range.
0000 to 0FFF (0 to 4,095)
16 to 31
Variable type
Sets the variable area for setting the zone data.
0002: Global general purpose variables (Address range: 0000
to 1FFC Hex)
0003: Input variables (address range: 0000 to 0FFC Hex)
0004: Output variables (address range: 0000 to 0FFC Hex)
0005: Position data (address range: 0000 to 27FE Hex
)
0006: Task variable 1 (address range: 0000 to 007C Hex)
0007: Task variable 2 (address range: 0000 to 007C Hex)
0008: Task variable 3 (address range: 0000 to 007C Hex)
0009: Task variable 4 (address range: 0000 to 007C Hex)
000A: Task variable 5 (address range: 0000 to 007C Hex)
000B: Task variable 6 (address range: 0000 to 007C Hex)
000C: Task variable 7 (address range: 0000 to 007C Hex)
000D: Task variable 8 (address range: 0000 to 007C Hex)
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...