67
System Parameters
Section 4-2
In the setting range and initial value columns, the upper value is in hexadeci-
mal while the lower value in parenthesis is in decimal.
Unit Parameters
Explanation
Specifies the upper limit for No. of tasks to be used. Task No. up to the value
set here can be used.
Note
This setting closely relates to the Unit's processing time. For details, see
Calculation Method for Unit Cycle
Explanation
Specifies the numbers of both parallel branching and simultaneous execution
commands in each motion task.
The number of branches specified in this parameter is used for each task.
Note
When P00004 bit 11 (number of parallel branches) is ON, P00M21 (number of
parallel branches per task) is used.
This setting affects the maximum number of branches for the PARALLEL (par-
allel execution) command. (It is limited by the value set here.) When the num-
ber of parallel branches in a motion program is smaller than the value set in
this parameter, the value obtained from dividing the value in the parameter by
the actual number of branches becomes the number of commands that can
be executed simultaneously for each row of each branched program.
The number of multiple execution commands in each unit cycle is applied to
the simultaneous execution.
Example: The program execution time is calculated as follows when the unit
cycle time is 2 ms, the number of parallel branches is 4, and 100 blocks (lines)
are executed in motion task 1 (assuming that the program contains only multi-
ple-execution commands that do not have wait time):
100 blocks/4 blocks
×
2 ms = 50 ms
(For details, see
6-1-3 Advancement of the Motion Program
Note
This setting closely relates to the Unit's processing time. For details, see
Calculation Method for Unit Cycle
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00001
5000h
No. of motion tasks
Data
Task
No
Data configuration
Setting range
00000001 to 00000008 Hex
(1 to 8)
Initial value
00000001 (1)
31
00
No. of motion tasks
No.
Address in MC
Unit
Name
Type
Unit
Immediate
updating
P00002
5001h
No. of parallel branches
Data
---
No
Data configuration
Setting range
00000001 to 00000008 Hex
(1 to 8)
Initial value
00000001 (4)
31
00
No. of parallel branches
Содержание CS1W-MCH71 -
Страница 2: ...CS1W MCH71 CJ1W MCH71 Motion Control Unit Operation Manual Revised June 2008 ...
Страница 3: ...iv ...
Страница 29: ...xxx ...
Страница 33: ...xxxiv ...
Страница 35: ...xxxvi ...
Страница 39: ...xl ...
Страница 69: ...24 Performance Section 1 7 ...
Страница 99: ...54 Connecting MECHATROLINK Devices Section 3 5 ...
Страница 283: ...238 Saving Data Section 5 4 ...
Страница 417: ...372 Command Details Section 6 3 ...