78
Unit Setup Area
Section 5-1
5-1
Unit Setup Area
5-1-1
Overview
The Unit Setup Area enables the user to set the functions of the Customizable
Counter Unit through initial software settings. Connect a Programming Device
to the Unit’s peripheral port and make the settings in DM 6600 to DM 6655 of
the Unit’s DM Area.
Note
It is not possible to make the settings for the Unit Setup Area in the Customiz-
able Counter Unit from a CX-Programmer using the PLC Setup functions.
Make the settings for in DM 6600 to DM 6655 from the PLC Memory Window
on the CX-Programmer.
Unit Setup Area
The Unit Setup Area consists of DM 6600 to DM 6655. These words are
divided according to function and enable timing as shown below.
Default Settings
The default setting (factory setting) for all words in the Unit Setup Area is
0000.
Resetting
All words in the Unit Setup Area can be reset to 0000 by turning ON
SR 25210 (Unit Setup Area Reset Bit) using the Programming Device in PRO-
GRAM mode.
Note
1.
When the DM Area is cleared by performing the memory clear operation
from a Programming Console, the Unit Setup Area is also reset.
2.
The Unit Setup Area can also be read from the user program. It cannot,
however, be written from the user program. Write to the User Setup Area
using a Programming Device.
3.
The Unit Setup Area settings are saved in flash memory. Therefore, even
if the super-capacitor’s saving time elapses, the data will be saved.
Address
Function
Enable timing
Operation for setting error
DM 6600 to DM 6604
Overall Unit Settings
Enabled at Startup
SR 24900 turns ON.
DM 6605 to DM 6614
Special I/O
DM 6615 to DM 6629
Overall Unit Settings
Enabled at Startup and when
operation starts
SR 24901 turns ON.
DM 6630 to DM 6639
Special I/O
DM 6640 to DM 6644
Overall Unit Settings
DM 6645 to DM 6655
Overall Unit Settings
Enabled whenever changed
SR 24902 turns ON.
Содержание CS1W-HCA12-V1
Страница 2: ......
Страница 6: ...vi...
Страница 20: ...xx Conformance to EC Directives 7...
Страница 38: ...18 Models and System Configurations Section 1 2...
Страница 78: ...58 Fail safe Circuits Section 3 5...
Страница 138: ...118 AR Area Section 6 4...
Страница 204: ...184 Improved Instructions Section 7 14...
Страница 222: ...202 Cycle Time Section 8 3...
Страница 240: ...220 Troubleshooting Flowcharts Section 9 5...
Страница 244: ...224 Precautions when Using the CX Programmer Appendix A...
Страница 252: ......
Страница 253: ......