;&'4&'-0)*'")<
Section 3-5
)*
3-5-1
Range Mode
If the Unit is configured to control the Outputs in Range Mode, this Mode can be
applied to Circular Counters or Linear Counters (refer to 3-2-2
and 3-2-3
for more information).
Example Range Mode with
Linear Counter
In this example four Ranges are specified. The configuration data of the Counter
shows that:
•
Output 0 must be ON for Counter Values within Range 0.
•
Both the Outputs 1 and 3 must be ON for Counter Values within Range 1.
•
Output 2 must be ON for Counter Values within Range 2.
•
Both the Outputs 0 and 3 must be ON for Counter Values within Range 3.
In the above example the Counter Value is within Range 1 and 3 and consequently
the Outputs 0, 1 and 3 are turned ON.
Counter Value
0
Range 0
Range 1
Range 2
Range 3
Output 0
Output 1
Output 2
Output 3
Range
Lower Range Limit
Upper Range Limit
Output ON
0
1
2
3
-20,000
-1,000
-5,000
6,000
-10,000
+19,000
11,000
+25,000
0
1, 3
2
0, 3
Minimum Count Limit
-2,147,483,648
(=80000000
H
)
Maximum Count Limit
+2,147,483,647
(=7FFFFFFF
H
)
Current
Counter Value
W902-E2-03.book Seite 67 Donnerstag, 7. Oktober 2004 2:06 14
Содержание CS1W-CT021
Страница 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Страница 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Страница 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Страница 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Страница 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Страница 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Страница 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...