Hardware Specifications of the Distributed Sensor Unit
Unit Address Setting Switch
This switch sets the Unit address (as a decimal number) of the E3NW-DS on the DS-Bus
network.
The setting range is 1 to 8. (Factory setting: 1)
If multiple Distributed Sensor Units are connected to the Sensor Communications Unit, set
the addresses of the Distributed Sensor Units in order starting from 1.
• The setting of the unit address switch is read only once when the power is turned ON.
Changing this setting after the power is turned ON will have no effect until after the next
time the power is turned ON.
• An error will occur and operation will not continue normally if the same Unit address is
assigned to more than one Unit.
Unit address setting switch