66
Section 4
Using th
e Dist
ribut
ed Sen
s
or Unit
E3NW-CRT
User’s Manual
Section 4
Mounting and Removing Distributed Sensor Units
4.
Secure the enclosed DIN Track
End Plates (PFP-M) onto the
ends so that there is no space
between them and the Units.
Finally, attach the protective cap
you removed in step 3 to the
Sensor Amplifier Unit on the far
right end.
Do not reverse the order of
steps 1 and 2, above. Doing so
may reduce the mounting
strength on the DIN Track.
After you have completed the above procedure, check to make sure that the
E3NW-DS is mounted securely into place.
Removal Procedure
Use the following procedure to remove the Unit.
1.
Slide the Sensor Amplifier Units to
separate them from the Distributed
Sensor Unit.
2.
Press in on the Distributed Sensor
Unit toward the DIN Track and lift up
to remove it.
DIN Track
End Plate
Protective cap
2
1
1
1
2
2
Do in order: step
1 and then step
Do not perform
step 2 first.