Chapter 8: Maintenance
See MotionBlox-40R on page 27 for locations of connectors.
5. Disconnect the 200/240 VAC supply cable from the eMB-40R AC Input connector.
6. Disconnect the eAIB XSYS cable from the eMB-40R XSYSTEM connector.
If the system was upgraded from an MB-40R to an eMB-40R, you may need to dis-
connect the XSYS cable and eAIB XSLV Adapter from the XSYSTEM connector.
7. Disconnect the IEEE 1394 cable from the eMB-40R SmartServo connector.
8. Disconnect any other cables, which may be connected to the eMB-40R, such as XIO, RS-
232, or any others.
Installing a New eMB-40R
1. Carefully remove the new eMB-40R from its packaging, check it for any signs of dam-
age, and remove any foreign packing materials or debris.
2. Carefully place the eMB-40R next to the robot.
3. Connect the 200/240 VAC supply cable to the eMB-40R AC input connector.
4. Connect the XSYS cable to the eMB-40R XSLV connector, or
Connect the eAIB XSYS cable to the eMB-40R XSYSTEM connector.
If you are upgrading from an MB-40R to an eMB-40R, connect the existing XSYS cable
to the eAIB XSLV Adapter, which connects to the eMB-40R XSYSTEM connector.
5. Connect the IEEE 1394 cable to the eMB-40R SmartServo/Servo connector.
6. Connect any other cables, which were connected to the eMB-40R, such as XIO, RS-232,
or any others.
7. Connect the 24 VDC supply cable to the eMB-40R +24 VDC input connector.
8. Switch on the 200/240 VAC input supply to the eMB-40R.
9. Switch on the 24 VDC input supply to the eMB-40R.
10. Switch on the SmartController EX, if present.
11. Once the system has completed booting, test it for proper operation.
8.9 Commissioning a System with an eMB-40R
Commissioning a system involves synchronizing the robot with the eMB-40R.
NOTE:
This section only applies to robots that have an eMB-40R amplifier. A
robot with an MB-40R amplifier does not need the ACE commissioning.
For a new system with an eMB-40R, the robot and the eMB-40R will have been commissioned
at the factory and should not need commissioning.
If you are replacing an MB-40R with an eMB-40R, you will need to commission the system.
In rare cases with a new robot with an eMB-40R, you may need to commission the system.
05624-000 Rev. K
Cobra 350 User's Guide
111