One CK3W Unit in the system supplies servo clock and phase clock signals to all the other Units.
The supply-source CK3W Unit must be installed to the CPU Rack.
Connect the Unit with the smallest address value to the CPU Rack because, by default, it is the supply
source of clock signals.
You may specify the Unit with a desired address as the clock supply source by setting the register.
If the Unit that serves as the clock supply source is connected to the Expansion Rack, an error occurs
because the CPU Unit cannot recognize clock signals.
If this error occurs, the Sys.Status register Sys.NoClocks becomes
1
.
3-4-5
Terminal Arrangement
This section describes the terminal arrangement of the digital I/O connection terminal block.
CK3W-MD7110
1
18
19
38
No. Signal
No. Signal
1
IN00
19
IN08
2
IN01
20
IN09
3
IN02
21
IN10
4
IN03
22
IN11
5
IN04
23
IN12
6
IN05
24
IN13
7
IN06
25
IN14
8
IN07
26
IN15
9
V1
27
V1
10
OUT00
28
OUT08
11
OUT01
29
OUT09
12
OUT02
30
OUT10
13
OUT03
31
OUT11
14
OUT04
32
OUT12
15
OUT05
33
OUT13
16
OUT06
34
OUT14
17
OUT07
35
OUT15
18
V2
36
G2
3 Configuration Units
3-51
CK3M-series Programmable Multi-Axis Controller User's Manual Hardware (O036)
3-4
Digital I/O Unit
3
3-4-5
T
erminal Arrangement
Содержание CK3M Series
Страница 6: ...Manual Structure 4 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 236: ...6 Troubleshooting 6 22 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 242: ...7 Inspection and Maintenance 7 6 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 284: ...Appendices A 42 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036...
Страница 285: ...I Index I 1 CK3M series Programmable Multi Axis Controller User s Manual Hardware O036 I...
Страница 287: ......