A Standard System Protocol
R-78
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
R-5
3Z4L Laser Micrometer Protocol
The 3Z4L Laser Micrometer Protocol is used to remotely make various settings or control the Laser
Micrometer connected to the Serial Communications Unit/Board via RS-232C cable.
The connections for the 3Z4L Laser Micrometer Protocol are shown below.
RS-232C Connection
Shown below are the settings of 3Z4L-3000, 3Z4L-4000-series DIP switches required to use the system
protocol sequences.
3Z4L-3000 Series
• DIP Switch 1
R-5-1
Connections
DIP Switch Settings
No.
Setting
Status
1
Baud rate
ON/OFF
2
ON/OFF
3
Handshaking procedure
ON/OFF
4
RS-232C interface use
selection
ON/OFF
5
ON/OFF
6
ON/OFF
Sensor
Signal cable
Controller
RS-232C Port
FG
SD
RD
RTS
CTS
DSR
DTR
SG
1
2
3
4
5
7
8
9
Pin No.
Serial Communications Unit/Board:
D-sub 9 pin (female)
Controller: D-sub
25 pin (female)
Signal
name
FG
TXD
RXD
RTS
CTS
DSR
SG
DTR
1
2
3
4
5
6
7
20
Pin No.
Signal
name
Serial Communications Board
(CS Series only)
Serial Communications Unit
(CS/CJ Series)
PLC PS
RS-232C
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...