6-7
6 No-protocol Mode
CJ-series Serial Communications Units Operation Manual for NJ-series CPU Unit(W494)
6-2
De
vice V
ariab
le
s f
o
r CJ-se
rie
s Unit and
System
-d
efin
ed V
ariab
les (No
-pr
o
to
col Mo
de)
6
6-2-1 De
vice
V
ar
iab
les f
or CJ-Ser
ies Unit
f
or System Set
tings
*1
When the default settings are used, the Baud Rate, Start Bits, Data Length, Stop Bits, Parity Yes/No and Parity
Even/Odd settings are disabled. To specify settings for these items to the settings other than the default, select
User settings.
Default settings are Baud Rate: 9,600 bps, Start Bits: 1 bit, Data Length: 7 bits, Parity: Even parity and Stop
Bits: 2 bits.
*2
When CTS control is enabled, the request to send signal (RTS) turns ON and the transmission starts after the
clear to send signal (CTS) turns ON. When CTS control is disabled, the request to send signal (RTS) turns ON
and the transmission starts without checking whether the clear to send signal (CTS) is ON.
*_P1_NopCRLFCfg
*_P2_NopCRLFCfg
BOOL
RW
No-Protocol CR
+ LF Specifica-
tion Setting
End code
P*_NopCRLFCfg/
P*_NopEndCodeYNCfg
00: No (specify number of
receive data bytes)
01: Yes
10: CR + LF specified
11: Prohibited
*_P1_NopEndCodeYN
Cfg
*_P2_NopEndCodeYN
Cfg
BOOL
RW
No-protocol
End Code
Inclusion Set-
ting
*_P1_NopRcvDatSzCf
g
*_P2_NopRcvDatSzCf
g
USINT
RW
Number of
Received Data
Bytes in No-
protocol Mode
0: 256 bytes (default)
Range: 1 to 255 bytes
Device variable for CJ-series Unit
Type
R/W
Name
Function
Port 1
Port 2
Содержание CJ1W-SCU22
Страница 192: ...4 Using Protocol Macros 4 56 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 250: ...6 No protocol Mode 6 22 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 460: ...A Standard System Protocol R 126 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494...
Страница 473: ...Index 1 CJ series Serial Communications Units Operation Manual for NJ series CPU Unit W494 I Index...