298
Sensor Terminals
Section 5-5
Node Number Settings
Set the node number with pins 1 through 4, as shown in the following table.
Note
The actual node number setting range depends on the type of PLC in which
the Master is mounted as well as the Master’s settings. Refer to
for details.
Compatible External
Devices and Cables
Remote Terminals with Connector Output Transistors use the XS8A-0441 and
XS8A
-
0442 Connectors (sold separately) to connect to external devices. Use
the following flowchart to check the compatibility of external devices and
cables. Refer to
3-4-3 Cable Connector Wiring and Assembly
for details on
the assembly, wiring, and installation of cable connectors.
Node number
Pin 4
(8)
Pin 3
(4)
Pin 2
(2)
Pin 1
(1)
0
OFF
OFF
OFF
OFF
1
OFF
OFF
OFF
ON
2
OFF
OFF
ON
OFF
3
OFF
OFF
ON
ON
4
OFF
ON
OFF
OFF
5
OFF
ON
OFF
ON
6
OFF
ON
ON
OFF
7
OFF
ON
ON
ON
8
ON
OFF
OFF
OFF
9
ON
OFF
OFF
ON
10
ON
OFF
ON
OFF
11
ON
OFF
ON
ON
12
ON
ON
OFF
OFF
13
ON
ON
OFF
ON
14
ON
ON
ON
OFF
15
ON
ON
ON
ON
Locking lever