background image

i

Monitor

Instruction Manual

C

English

Eespañol

7 series Blood Pressure Monitor

Model BP761

Instruction Manual

English

.

o, Kyoto, 617-0002 JAPAN

est, IL 60045 U.S.A.

e in China/Hecho en China

Español

2298830-6B

El producto incluye:

Monitor

Manual de Instrucciones

Quick S
Guía re

Product includes:

7 series Blood Pressure Monitor

Model BP761

Instruction Manual

Содержание BP761

Страница 1: ...English Espa ol...

Страница 2: ...Monitor Battery Set ComFit Cuff El producto incluye Monitor Juego de Pilas Brazalete ComFit Product includes...

Страница 3: ...s a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population The device detects the appearance of irregular heartbeats during measurement and gives a war...

Страница 4: ...cy pre eclampsia renal diseases Note that PATIENT motion trembling shivering may affect the measurement reading Do not use the device on the injured arm or the arm under medical treatment Do not apply...

Страница 5: ...is device on infants or persons who cannot express their intentions Do not use the device for any purpose other than measuring blood pressure Use only the approved arm cuff for this device Use of othe...

Страница 6: ...es of batteries Do not use new and used batteries together Remove the batteries if the device will not be used for three months or more General Precautions Do not forcibly crease the arm cuff or the a...

Страница 7: ...jack for optional AC adapter Display Memory symbol USER ID symbol Average value symbol Systolic blood pressure Diastolic blood pressure Transfer indicator Memory full symbol OK symbol Heartbeat symbol...

Страница 8: ...ythm detected while the monitor is measuring the systolic and diastolic blood pressure If the irregular heartbeat symbol displays with your measurement results we recommend you consult your physician...

Страница 9: ...ure color indicator will light in green 2013 ESH ESC Guidelines for the management of arterial hypertension Definitions of hypertension by office and home blood pressure levels These are from statisti...

Страница 10: ...allation 1 Remove the battery cover 2 Insert 4 AA batteries as indicated in the battery compartment 3 Replace the battery cover Notes When the low battery symbol appears on the display turn the monito...

Страница 11: ...utton twice The year flashes on the Date Time display 2 Push or button to change the year Push button to confirm the year and then the month flashes Repeat the same steps to change the month day hour...

Страница 12: ...air jack securely 2 Apply the arm cuff to your left upper arm The bottom edge of the arm cuff should be 1 2 inch 1 to 2 cm above the elbow Air tube is on the inside of your arm and aligned with your m...

Страница 13: ...oom temperature Avoid bathing drinking alcohol or caffeine smoking exercising or eating 30 minutes before taking a measurement Sit on a chair with your feet flat on the floor Sit upright with your bac...

Страница 14: ...till and quiet while taking a measurement The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2 1 Select your USER ID 1...

Страница 15: ...2 3 minutes before taking another measurement Waiting between measurements allows the arteries to return to the condition prior to taking a measurement Using the Guest Mode The monitor stores measure...

Страница 16: ...Blood Pressure This monitor is not intended to be a diagnostic device Always consult your physician Self diagnosis of measurement results and self treatment are dangerous Read If your systolic pressu...

Страница 17: ...only 2 measurement values in the memory for that period the average will be based on these 2 values If there is 1 measurement value in the memory for that period this is displayed as the average If th...

Страница 18: ...stored in the memory To view the older values To view the more recent values To View the Average Value 1 Select your USER ID 1 or 2 2 Press and hold the button for more than 3 seconds Notes If the pr...

Страница 19: ...ng the OMRON Wellness software for the first time please visit www omronwellness com for the initial set up instructions 1 Download and install onto your smartphone the free Omron Wellness APP 2 Open...

Страница 20: ...fer indicator is flashing on the display The OK symbol and will flash when pairing is completed Any readings currently saved in the blood pressure monitor s memory will automatically be transfered to...

Страница 21: ...l appear on the display 2 While holding the button down press the START STOP button for more than 2 seconds The OK symbol and will flash if your device has been unpaired Notes Unpairing your device wi...

Страница 22: ...s Stored in Memory The values stored in the memory are deleted by USER ID 1 Select your USER ID 1 or 2 2 Press the Memory button while the memory symbol appears 3 While holding the button down press t...

Страница 23: ...ent Repeat the steps in section 3 3 If this error continues to appear contact your physician Movement during measurement Carefully read and repeat the steps in section 3 3 The batteries are low You sh...

Страница 24: ...not been inflated sufficiently Repeat measurement Remain still and do not talk during measurement Refer to section 3 3 If E2 appears repeatedly inflate the arm cuff manually until it is 30 to 40 mmHg...

Страница 25: ...h or too low Blood pressure varies constantly Many factors including stress time of day and how you wrap the cuff may affect your blood pressure Review the section 1 2 and section 3 3 The destination...

Страница 26: ...ot wash the device and any components or immerse them in water Do not use gasoline thinners or similar solvents to clean the device Use a soft and dry cloth or a soft and moistened cloth and neutral s...

Страница 27: ...2 Gently fold the air tube into the arm cuff Note Do not bend or crease the air tube excessively Do not store the device in the following situations If the device is wet Locations exposed to extreme...

Страница 28: ...5 Maintenance and Storage EN 5 3 Optional Medical Accessories Arm Cuff Arm circumference 9 17 22 42 cm AC Adapter ComFitTM Cuff CFX WR17 Model HEM FL31 HEM ADPTW5...

Страница 29: ...t the AC adapter plug into the AC adapter jack on the rear side of the monitor 2 Plug the AC adapter into an electrical outlet To disconnect the AC adapter unplug the AC adapter from the electrical ou...

Страница 30: ...4 AA batteries 1 5V or optional AC adapter INPUT AC100 240V 50 60Hz 0 12A Battery life Approximately 1000 measurements using new alkaline batteries Operating temperature humidity 50 F to 104 F 10 C t...

Страница 31: ...not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular instal...

Страница 32: ...this Product before using this Product or do not use this Product around the other wireless devices The Bluetooth Smart word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any...

Страница 33: ...only responsibility and your only remedy under the above warranty To obtain warranty service contact Customer Service by calling 1 800 634 4350 for the address of the inspection center and the return...

Страница 34: ...Healthcare conform to this IEC60601 1 2 2007 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than those specified...

Страница 35: ...power quality should be that of a typical commercial and or hospital environment Surge IEC 61000 4 5 1 kV line s to line s 2 kV line s to earth 1 kV line s to line s 2 kV line s to earth Mains power...

Страница 36: ...mobile RF communications equipment should be used no closer to any part of the OMRON BP761 including AC adapter including cables than the recommended separation distance calculated from the equation...

Страница 37: ...ions equipment Output Power of Transmitter in Watt Separation distance according to frequency of transmitter in meter 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 5GHz d 2 3 0 01 0 12...

Страница 38: ...N Q P O W E K L H G A G I H J C D B F X...

Страница 39: ...1 2 b c d b a A L...

Страница 40: ...Manufactured for Fabricado para...

Отзывы: