Chapter 4 Command Description
4-16 Get MIN_AMP (for all range)(91Hex)
3D TOF Sensor Module B5L User's Manual (No. E596)
4-16 Get MIN_AMP (for all range)(91Hex)
Acquires the minimum amplitude value currently specified
.
Command (from host to this product)
Synchroniz
ation code
Command
No.
Data length
FEHex
91Hex
00Hex
00Hex
Response (from this product to host)
Synchroniz
ation code
Response
code
Data length
Data
FEHex
Normal
end: 00Hex
00Hex
00Hex
00Hex
01Hex
See below for details
Error:
FFHex to
F0Hex
00Hex
00Hex
00Hex
00Hex
・
Data details
The minimum amplitude value (for all range) currently specified is returned in 1 byte
.