Chapter 4: System Installation
WARNING:
Under no circumstances should you run a robot system, in pro-
duction mode, with all three jumpers installed. This would leave the system
with no E-Stops.
Cable Installation Overview
Power requirements for the SmartVision MX industrial PC are covered in that user guide. For
24 VDC, both the robot and a SmartVision MX can usually be powered by the same power
supply.
Step
Connection
Part
1
Connect eAIB XSYSTEM cable to XSYSTEM on eAIB or eMB-40/60R.
A
2
Connect a user E-Stop or Muted Safety Gate to the eAIB XSYSTEM cable XUSR
connector or
B
2a
verify XUSR jumper plug is installed in eAIB XSYSTEM cable XUSR connector.
C
3
Connect Front Panel cable to Front Panel and eAIB XSYSTEM cable XFP con-
nector or
D, E
3a
if no Front Panel, install FP jumper on eAIB XSYSTEM cable XFP connector.
See NOTE after table.
F
4
Connect T20 adapter cable to eAIB XSYSTEM cable XMCP connector or
J, K
4a
if no T20, install XMCP jumper
or
T20 Adapter Cable with T20 bypass plug.
G
or
H
5
Connect user-supplied ground to robot. See robot user's guide for location.
n/a
6
Connect 200-240 VAC to AC Input on eAIB Interface Panel; secure with clamp.
L
7
Connect 24 VDC to DC Input on Interface Panel.
N2,
M
7a
Connect 24 VDC and shield ground to SmartVision MX. See SmartVision MX
user's guide for location.
N1,
M
8
Connect RS232 cable from SmartVision MX to Anyfeeder.
P
9
Connect Ethernet cable between eAIB or eMB-40/60R and SmartVision MX. A
switch can be used between the two.
S
10
Connect camera and cable to SmartVision MX. Use USB PoE 1 on MX.
T
11
Connect 24 VDC Servo cable to DC Input on AnyFeeder interface panel.
U, V
12
Connect an 8 mm OD air line to the pneumatic connector, SX240, SX340.
X
NOTE:
A front panel ships with each fixed (non-mobile) robot system, but you can
choose not to use it if you replace its functionality with equivalent circuits. That is
beyond the scope of this guide.
AnyFeeder
Integration
Guide
- Page
19