4-122
4-3 Functions When Option PG Board (3G3AX-PG01) Is Used
4
Functions
Control Block Diagram
Pulse Train Position Control Mode
To use this function, set V/f characteristics selection A044 to "05" (V2), and V2 control mode selec-
tion P012 to "01" (pulse train position control).
("Sensor vector control" can be selected for 1st control only.)
Select a pulse train position command input mode in pulse train mode selection P013.
P039
Speed limit value in
torque control (forward)
0.00 to 99.99/100.0 to 400.0
0.00
Hz
P040
Speed limit value in
torque control (reverse)
0.00 to 99.99/100.0 to 400.0
0.00
Hz
P036
Torque bias mode
00: Disabled
01: Set via the Digital Operator
02: Set via terminal FE
00
⎯
P037 Torque
bias
value
-200. to +200. (0.4 to 55 kW)
-180. to +180. (75 to 132 kW)
Enabled when P036 = 01
0.
%
P038
Torque bias polarity
selection
00: As per sign
01: Depends on the RUN direction
00
⎯
C001 to C008
Multi-function inputs
1 to 8 selection
52: ATR (torque reference input permission)
⎯
⎯
Related functions
d009, d010, d012
Parameter No.
Function name
Data
Default setting
Unit
ATR terminal
Torque reference input
Torque bias
Torque limit
Torque reference
(Reference value for current control)
Speed control
(P control)
Speed
monitor
Speed limit
value
Speed detection
value
The speed control (P control) operates when a
speed detection value exceeds the limit value.
Parameter No.
Function name
Data
Default setting
Unit
P012
V2 control mode selection
01: APR (pulse train position control mode)
00
⎯
P013
Pulse train mode selection
00: Mode 0 (pulse train with 90
°
phase
difference)
01: Mode 1 (forward/reverse c
pulse train)
02: Mode 2 (forward pulse train + reverse
pulse train)
Содержание 3G3RX Series
Страница 1: ...Cat No I560 E1 03 USER S MANUAL SYSDRIVE RXSERIES High function General purpose Inverter ...
Страница 2: ......
Страница 17: ...Chapter 1 Overview 1 1 Functions 1 1 1 2 Appearance and Names of Parts 1 4 ...
Страница 22: ......
Страница 23: ...Chapter 2 Design 2 1 Installation 2 1 2 2 Wiring 2 6 ...
Страница 48: ......
Страница 108: ......
Страница 324: ......
Страница 325: ...Chapter 5 Maintenance Operations 5 1 Protective Functions and Troubleshooting 5 1 5 2 Warning Function 5 10 ...
Страница 337: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 1 ...
Страница 348: ......
Страница 349: ...Chapter 7 Specifications 7 1 Standard Specification List 7 1 7 2 Dimensional Drawing 7 6 7 3 Options 7 14 ...
Страница 358: ...7 9 7 2 Dimensional Drawing 7 Specifications 3G3RX A2300 A4300 368 79 265 310 10 510 540 2 φ10 195 45 80 265 ...
Страница 360: ...7 11 7 2 Dimensional Drawing 7 Specifications 3G3RX A2550 380 670 700 2 φ12 12 380 480 250 352 79 ...
Страница 361: ...7 12 7 2 Dimensional Drawing 7 Specifications 3G3RX A4750 A4900 2 φ12 2 12 300 390 268 700 79 670 357 ...
Страница 362: ...7 13 7 2 Dimensional Drawing 7 Specifications 3G3RX A411K A413K 2 φ12 2 12 380 480 270 740 79 710 480 ...
Страница 369: ...7 20 7 3 Options 7 Specifications 3G3AX RBC4001 3G3AX RBC6001 100 150 280 300 5 70 100 70 150 390 410 5 ...
Страница 392: ......
Страница 393: ...Appendix Appendix 1 Parameter List App 1 Appendix 2 Product Life Curve App 41 Appendix 3 Life Alarm Output App 42 ...
Страница 436: ......
Страница 437: ...Index ...
Страница 441: ......