24
7.2.
Register Number
In 3G3MX2-V1, (Register address)
=(
Register number
)-
1
。
Register
No.
Parameter
No.
Monitor or setting data
Data
resolution
Register
No.
Parameter
No.
Monitor or setting data
Data
resolution
0001h F001(HIGH)
0002h F001(LOW)
Inverter status
0003h
-
00: Default
02: Stop
03: Run
04: Free-run stop (FRS)
05: Jogging
06: DC injection braking
07: Retry
08: Trip
09: Undervoltage
-
0003h
-
0: Initial status
2: Stop
3: Run
4: Free-run stop
5: Jogging
6: DC injection
braking
8: Trip
9: During UV
-
PID feedback
(Enable when A076 = 02)
0005h
-
0 ~ 1000
0.1[%]
0006h
-
0~10000
0.01[%]
1001h d001(HIGH)
1002h d001(LOW)
Output current monitor
1003h
d002
0 ~ 2000
0.1[%]
1003h
d002
0~65530
0.01[A]
Rotation direction monitor
1004h
d003
00: Stop
01: Forward
02: Reverse
-
1004h
d003
0: Stop
1: Forward
2: Reverse
-
1005h d004(MSB)
1005h d004(HIGH)
1006h d004(LSB)
1006h d004(LOW)
Multi-function input monitor
1007h
d005
0 to 63
Multi-function input status, Bit 0 =
[1] to Bit 4 = [5]
-
1007h
d005
2
0
︓Terminal S1
~2
6
︓Terminal S7/EB
ビット
Multi-function output
monitor
1008h
d006
0 to 7
Multi-function output status,
Bit 0 = [P1]
Bit 1 = Not used.
Bit 2 = [MA]
-
1008h
d006
2
0
︓Terminal P1
~2
1
︓Terminal P2
2
6
︓Relay output terminal MA
ビット
1009h d007(MSB)
1009h d007(HIGH)
100Ah d007(LSB)
100Ah d007(LOW)
Output voltage monitor
100Ch
d013
0 ~ 20000
0.01[%]
1011h
d013
0~6000
0.1[V]
100Eh d016(MSB)
1015h d016(HIGH)
100Fh d016(LSB)
1016h d016(LOW)
1010h d017(MSB)
1017h d017(HIGH)
1011h d017(LSB)
1018h d017(LOW)
Fin temperature monitor
116Ah
d018
0 ~ 2000
0.1[ ℃ ]
1019h
d018
-200~+1500
0.1[°C]
Fault frequency monitor
0011h
d080
0 ~ 65535
-
0011h
d080
0~65535
1[回]
DC voltage monitor
116Ch
d102
0 ~ 9999
0.1[V]
1026h
d102
0~10000
0.1[V]
Electronic thermal monitor
116Dh
d104
0 ~ 1000
0.1[%]
1028h
d104
0~1000
0.1[%]
0012h
Fault Monitor 1 Fault
0013h
Fault Monitor 1 Inverter
0014h
0~40000(LOW)
0015h
0~58000(HIGH)
0016h
Trip monitor 1: Current
0.1[A]
0016h
Output Current
0.01[A]
0017h
Trip monitor 1: Voltage
1[V]
0017h
DC Voltage
0.1[V]
0018h
Trip monitor 1: Run time (MSB)
0018h
Total RUN Time (HIGH)
0019h
Trip monitor 1: Run time (LSB)
0019h
Total RUN Time (LOW)
001Ah
Trip monitor 1: ON time (MSB)
001Ah
Total Power ON Time (HIGH)
001Bh
Trip monitor 1: ON time (LSB)
001Bh
Total Power ON Time (LOW)
001Ch
Fault Monitor 1 Fault
001Dh
Fault Monitor 1 Inverter
Status
001Eh
0~40000(LOW)
001Fh
0~58000(HIGH)
0020h
Trip monitor 2: Current
0.1[A]
0020h
Output Current
0.01[A]
0021h
Trip monitor 2: Voltage
1[V]
0021h
DC Voltage
0.1[V]
0022h
Trip monitor 2: Run time (MSB)
0022h
Total RUN Time (HIGH)
0023h
Trip monitor 2: Run time (LSB)
0023h
Total RUN Time (LOW)
0024h
Trip monitor 2: ON time (MSB)
0024h
Total Power ON Time (HIGH)
0025h
Trip monitor 2: ON time (LSB)
0025h
Total Power ON Time (LOW)
0026h
Fault Monitor 1 Fault
0027h
Fault Monitor 1 Inverter
0028h
0~40000(LOW)
0029h
0~58000(HIGH)
002Ah
Trip monitor 3: Current
0.1[A]
002Ah
Output Current
0.01[A]
002Bh
Trip monitor 3: Voltage
1[V]
002Bh
DC Voltage
0.1[V]
002Ch
Trip monitor 3: Run time (MSB)
002Ch
Total RUN Time (HIGH)
002Dh
Trip monitor 3: Run time (LSB)
002Dh
Total RUN Time (LOW)
002Eh
Trip monitor 3: ON time (MSB)
002Eh
Total Power ON Time (HIGH)
002Fh
Trip monitor 3: ON time (LSB)
002Fh
Total Power ON Time (LOW)
1014h F002(MSB)
1103h F002(HIGH)
1015h F002(LSB)
1104h F002(LOW)
1501h F202(MSB)
2103h F202(HIGH)
1502h F202(LSB)
2104h F202(LOW)
1016h F003(MSB)
1105h F003(HIGH)
1017h F003(LSB)
1106h F003(LOW)
1503h F203(MSB)
2105h F203(HIGH)
1504h F203(LSB)
2106h F203(LOW)
Operator rotation direction
selection
1018h
F004
0: Forward
1: Reverse
-
1107h
F004
00: Forward
01: Reverse
-
Acceleration time 1
1 to 300000
The second decimal place is ignored
when the value is over 10000 (100.0
seconds).
0.01[s]
0~360000
0.01[s]
2nd acceleration time 1
Deceleration time 1
2nd deceleration time 1
0.1[Hz]
0.01[Hz]
1[h]
1[h]
1[h]
1[h]
Fault monitor 3
0026h
d083
Trip monitor 3: Factor code
-
d083
-
0028h
Trip monitor 3: Frequency
-
001Eh
Trip monitor 2: Frequency
0.1[Hz]
0.01[Hz]
1[h]
1[h]
Fault monitor 2
001Ch
d082
Trip monitor 2: Factor code
-
d082
1[h]
1[h]
Power ON time monitor
0 ~ 999999
1[h]
0~999000
1[h]
Fault monitor 1
0012h
d081
Trip monitor 1: Factor code
-
d081
-
0014h
Trip monitor 1: Frequency
0.1[Hz]
0.01[Hz]
1[h]
1[h]
1[h]
1[h]
Output frequency monitor
(after conversion)
0 ~ 3996000
0.01
0~3999600 (In the high-frequency
mode︓~5799420)
0.01
Total RUN time
0 ~ 999999
1[h]
0~999000
1[h]
0.01[Hz]
PID feedback value monitor
(A075 PID scale)
0 ~ 999900
0.01[%]
0~100000
0.1
Output frequency monitor
1002h
d001
0 ~ 4000
0.1[Hz]
0~40000 (In the high-frequency
mode︓~58000)
Function name
3G3JX
3G3MX2-V1
Frequency reference
(Enable when A001 = 03)
0002h
-
0 ~ 4000
0.1[Hz]
0 to Maximum frequency
0.01[Hz]
Содержание 3G3JX
Страница 1: ...Simple Compact Inverters JX series Replace Guide From 3G3JX to 3G3MX2 3G3MX2 A 3G3JX A I924 E1 01...
Страница 15: ...15 3G3JX Series 3G3MX2 V1 Series Model 3G3JX A2037 A4037 Model 3G3MX2 A2037 V1 A4040 V1...
Страница 32: ...2019 0919 0919 I924 E1 01 Note Do not use this document to operate the Unit...