Hardware reference
HARDWARE REFERENCE MANUAL
58
Revision 5.0
3.2
All units
3.2.1
System installation
fig. 3
A Trajexia system consists of these units:
•
A Power Supply Unit.
•
A TJ2-MC__ (Machine Controller Unit).
•
Up to 7 expansion units.
•
A TJ1-TER (Terminator Unit).
The expansion units (unit numbers 0-6) can be arranged in any order. The
TJ2-MC__ autodetects all units.
A Trajexia system with a TJ2-MC__ can include:
•
0 to 4 TJ1-ML__ units (MECHATROLINK-II Master Unit).
•
0 to 1 TJ2-ECT__ units (EtherCAT Master Unit)
•
0 to 7 TJ1-FL02 units.
•
0 to 7 TJ2-KS02 units.
•
0 or 1 TJ1-PRT (PROFIBUS-DP Slave Unit) or TJ1-DRT units
(DeviceNet Slave Unit)
1
.
•
0 or 1 TJ1-CORT units (CANopen Master Unit).
-1
Unit number:
0
1
2
3
4
5
6
1. Trajexia does not support both a TJ1-PRT and a TJ1-DRT unit in the same
system.