10355060_V_1_0.DOC
10/10
Occupation balanced XLR-connection:
2
1
3
1
2
3
Balanced use with XLR connectors
1 = Ground / Shield
2 = Hot (+)
3 = Cold (-)
For unbalanced use pin 1 and pin 3 have to be bridged
Input
Output
• If there is noise please use the Ground Lift-switch You can also adapt the Input-level (0dB for e.g. guitars, -
20dB for line-instruments, -40dB for speakers).
• Connect the microphone input of your stage mixer to the Output-socket.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Frequency range:
15 Hz - 30 kHz
Input impedance:
50 kOhms
Output impedance:
600 Ohms
Frequency range:
15 Hz - 30 kHz
S/N-ratio:
>95 dB
Please note: Every information is subject to change without prior notice. 05.04.2005 ©