background image

iConverter

®

 10/100M Media Converter

and

Network Interface Device

STANDALONE AND PLUG-IN MODULE

USER MANUAL

Release 3.4

Содержание Omnitron iConverter 10/100M

Страница 1: ...iConverter 10 100M Media Converter and Network Interface Device STANDALONE AND PLUG IN MODULE USER MANUAL Release 3 4...

Страница 2: ...ferences 13 3 4 2 Setting SNMP Preferences 16 3 4 3 Management Processor VLAN Support 19 3 4 4 Enabling Disabling Soft switch Reload 19 3 4 5 Access the 10 100M Remotely 21 3 5 Verify Operation 23 4 0...

Страница 3: ...vides information on the installation and configuration of the module using the command line interface serial console For ongoing network management Omnitron Systems recommends NetOutlook an SNMP base...

Страница 4: ...l forced modes for half and full duplex The UTP port can be enabled or disabled via network management A port disabled with the Port Access Control feature will still connect and allow 802 3ah OAM or...

Страница 5: ...detailed instructions Configure DIP switches Section 3 2 Installing the Module and Connecting Cables Section 3 3 Configure Module via Command Line Interface Section 3 4 Verify Operation Section 3 5 Wh...

Страница 6: ...standalone module Left Right Up Down Switch Left Down Factory Default Right Up SW1 Off Pause Disable On Pause Enable SW2 FDX Fiber Full Duplex HDX Fiber Half Duplex SW3 AN UTP Auto Negotiate Man UTP M...

Страница 7: ...t provide the proper signal to indicate its own mode of operation this DIP switch should be set to the UTP Manual mode Man position Manual mode requires manually configuring the UTP port to match the...

Страница 8: ...the previous page for a detailed explanation 3 2 1 6 SW6 SW7 SW8 Link Modes These three DIP switches configure the link mode settings The following table details possible Link Mode DIP switch configur...

Страница 9: ...ckplane illustrations in Section 2 1 3 3 2 2 3 SW4 Master Slave Auto Select and Slave Only M SL SL When multiple management modules such as the NMM and the 10 100M or multiple self managed modules suc...

Страница 10: ...ated wire not supplied with a 14 AWG gauge minimum Cut the power cable to the length required Strip approximately 3 8 of an inch of insulation from the power cable wires Connect the power cables to th...

Страница 11: ...nal and select the correct COM Port in the HyperTerminal Connect To window Set the PC s serial port to the following Bits Per Second 57 600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NO...

Страница 12: ...Number 1 Enter Choice H elp E x it A new 10 100M module does not have a password and will skip the Password Entry screen and go straight to the Management Options screen If a password has been set the...

Страница 13: ...er Choice Management Options Screen 0 H elp E x it To configure the IP address of the 10 100M select 1 at the IP and Control Preferences screen and press ENTER Backspace over the existing value type t...

Страница 14: ...ptions Screen 0 H elp E x it To enable DHCP client select 1 at the Other Networking Features screen and follow the screen prompts to enable DHCP To save the new values select 0 and press ENTER to retu...

Страница 15: ...ithout password protection on the Serial Console Port It is highly recommended that the network administrator set a password in order to prevent unauthorized access to the unit The password can be any...

Страница 16: ...lect 6 and press ENTER to Save Preference Changes 3 4 2 Setting SNMP Preferences To set the SNMP Preferences for the 10 100M module select 4 from the Management Options screen press ENTER to enter the...

Страница 17: ...then follow the screen prompts The SNMP Write Community Name is necessary for writing data to the 10 100M The name can be any 1 32 character alphanumeric string To set the SNMP Write Community Name se...

Страница 18: ...are used to report events that occur during the operation of a network and may require the attention of the network administrator The 10 100M is capable of sending SNMP traps to up to eight different...

Страница 19: ...t Disabled 2 Enable Disable Keep Alive Trap Disabled 3 Keep Alive Trap interval 10 600 secs 10 4 Enable Disable SW1 Switch Block Enabled 5 Serial Baud Rate 57600 bps 6 Enable Disable VLAN Support Disa...

Страница 20: ...h Reload function select 8 at the IP and Control Preferences screen press ENTER and then follow the screen prompts to change the setting IP and Control Preferences Screen iConverter Serial Agent 1 Set...

Страница 21: ...management software See Setting SNMP Preferences Section 3 4 2 on how to configure the required parameters NetOutlook Chassis View and Trap Log Screens 3 4 5 2 Accessing the 10 100M via Telnet The 10...

Страница 22: ...ware via the Serial Console Port To update the 10 100M firmware from the Serial Console Port select 10 at the Management Options screen press ENTER The 10 100M will display the following Management Op...

Страница 23: ...modules has been established A blinking LED indicates the presence of data The UTP 10 100 LED indicates the module has established a connection across its UTP port A blinking LED indicates the presenc...

Страница 24: ...e 10 100M module is installed NOTE Module configuration is also available using NetOutlook Chassis Selection iConverter Serial Agent Number Chassis Name 1 NMM 2 Not Available 3 Not Available 4 Not Ava...

Страница 25: ...22 N A 8 N A 9 N A 10 N A 11 N A 12 N A 13 N A 14 N A 15 N A Module to View 1 22 Chassis Selection 0 R eset H elp E x it 5 Chassis View 1 Slot iConverter Serial Agent Chassis Number 1 Slot Model Type...

Страница 26: ...14 Not Available 6 BP Master On 15 Not Available 7 UTP 10 Link Off 16 Not Available 8 UTP 100 Link Off OAM settings 9 UTP FDX Off 17 IP Protocol State On 18 Management Mode Secure OAM Toggle Switch 1...

Страница 27: ...ol State On 18 Management Mode Secure OAM Toggle Switch 1 16 I dentifier R eset H elp P ortStat Port C tl Mode 1 OAM Off 2 Auto Secure OAM 3 Auto ah OAM 4 Secure OAM 5 ah OAM 3 The 10 100M module supp...

Страница 28: ...nable On 4 Configure Tag VLAN Control 5 Configure VLAN Membership Bandwidth Control 6 Save TAG VLAN parameters 7 Configure 802 3ah parameters 21 Ingress rate Fiber No Limit 8 Configure 802 3ah events...

Страница 29: ...h are available Module iConverter 10 100M iConverter Serial Agent Identifier Chassis Number 1 Port VLAN Path Setup Slot Number 11 Model Number 8919 0 11 Fiber to UTP Enable On 12 Fiber to BP A Enable...

Страница 30: ...nced Options SFF 8472 Compliance 4 3 3 2 SFP A2 Information Display This section displays decoded SFP data collected for the following statistics Measured Temperature Measured Vcc Measured Bias Measur...

Страница 31: ...FF FF FF E0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF F0 FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF FF Enter Previous Screen 0 n ext page H elp E x it n SFP Information iConverter 10 100M iCo...

Страница 32: ...e Local Status section displays the status of the Fiber and UTP ports of the 802 3ah enabled local device The local device is controlled directly by SNMP Telnet or via the Serial Port and has the abil...

Страница 33: ...If Yes is displayed the receive link is down If No the receive link is up OAM Mode Indicates the OAM mode Active or Passive of the remote partner Supports Indicates the supported options Variable Acc...

Страница 34: ...4 Frame Threshold 0 frames 5 Frame Period Window 0 second 0 frames 6 Frame Period Threshold 0 frames 7 Frame Seconds Summary Window 0 seconds 8 Frame Seconds Summary Threshold 0 seconds UTP 9 Symbol...

Страница 35: ...traffic The management traffic is simply enabled or disabled at each port By default traffic flows between all ports on the module Using the Port VLAN settings data will only be forwarded across the e...

Страница 36: ...3ah parameters 21 Ingress rate Fiber No Limit 8 Configure 802 3ah events 22 Egress rate Fiber No Limit 9 SFP Information 23 Ingress rate UTP No Limit 10 cNode Loopback 24 Egress rate UTP No Limit Ent...

Страница 37: ...agged packets ingressing a port are processed Selecting the PVID option causes the PRI and PVID user specified values to be used as the packet s VLAN ID VID for processing of the packet Selecting the...

Страница 38: ...Tagged Packets Use PVID 9 Ingress Security Low 24 Ingress Security Low 10 Egress Policy Pass 25 Egress Policy Pass BP A 11 Port Priority PRI 0 12 PVID Port VLAN ID 2 13 Tagged Packets Use PVID 14 Ingr...

Страница 39: ...ing option 5 from the Port configuration screen The VLAN Membership screen will be displayed VLAN Membership iConverter 10 100M iConverter Serial Agent Identifier Chassis Number 1 Slot Number 1 Model...

Страница 40: ...bership No 3 UTP Port Membership No 4 BP A Port Membership No 5 BP B Port Membership No 6 Mngmnt Port Membership No 7 Submit Entry As Defined Enter Choice Previous Screen 0 H elp E x it Membership Ent...

Страница 41: ...Entry 1 1 VLAN ID 100 2 Fiber Port Membership Yes 3 UTP Port Membership No 4 BP A Port Membership No 5 BP B Port Membership No 6 Mngmnt Port Membership No 7 Submit Entry As Defined Enter Choice Previo...

Страница 42: ...ode Loopback The 10 100M has implemented Iometrix cNode Level 1 agent for testing performance metrics The agent recognizes measurement packets and loops them back to the sending cNode device Iometrix...

Страница 43: ...mal Off Off 8 Symm Fault Det Normal Off Off LED 9 BP A Enabled BP A Disabled On On 1 Power On 10 BP B Enabled BP B Disabled On On 2 Power Supply 1 Off 11 Not Available 3 Power Supply 2 Off 12 Slave On...

Страница 44: ...s PRI 0 1 2 3 4 5 6 7 Power Requirements DC Power 1 0A 3 3VDC Nominal 0 6A 9VDC Voltage Range 8 15VDC DC Power Connector Power supplied by backplane 2 5mm Barrel Connector or Terminal Connector AC Pow...

Страница 45: ...illuminate after installation is complete Possible Causes A Verify the Link Mode selection is set to Link Segment LS Until a stable link is established leave the Link Mode configured for LS After a L...

Страница 46: ...egment may cause the UTP 10 100 LED not to turn ON B Verify the iConverter 10 100M UTP port is configured with the proper settings based on the attached device AN or MAN 10 or 100 HD or FD C Verify th...

Страница 47: ...to defects resulting from improper or inadequate use and or maintenance of the equipment by Buyer Buyer supplied equipment Buyer supplied interfacing unauthorized modifications or tampering with equip...

Отзывы: