background image

4 port UHF RFID reader/writer   

User manual   

  

Connection diagram   
 

 

 
 

 

RS232 

 The reader provides RS232 communication interface to communicate with PC 

The data format of RS232 is 8 data bits, one start bit , one stop bit and no parity bit; 
Data rate can be    9600,19200,57600 and 115200. 

   

TCP-IP  

 
This reader supports RJ45 (Ethernet) interface. 
 

DB15 definition : 

 

 

DB15 pin assignment   

Pin 1  2 

5  6  7  8 

function Output 2 Output 1 

GND 

Output    4  Output 3 

GND 

Input 1  Input 2 

Pin  

10 

11 

12 

13 

14 

15 

 

function  GND A+(RS485) 

B-(RS485)  GND 

spare  spare 

spare 

 

 

 

 

 

 

 

 

 

 

 
 

4 antenna port   

power

RS232

GPIO 

TCP/IP 

OMT724 UHF Reader/writer RS232

Содержание OMT724

Страница 1: ...e stop bit and no parity bit Data rate can be 9600 19200 57600 and 115200 TCP IP This reader supports RJ45 Ethernet interface DB15 definition DB15 pin assignment Pin 1 2 3 4 5 6 7 8 function Output 2...

Страница 2: ...low GND Input 2 Input 1 Specification PC enquiry Reader input Input status command as below Head Addr Len Cmd Check 0x0A FF 0x02 0x2E C7 When reader received it will get response as below 1 When 2 Inp...

Страница 3: ...state of the appointed address EPC GEN2 ISO18000 6C tag Multi tag identification search all the tags in the detection range and read the EPC supports 96 bits EPC Single tag initialization define the...

Страница 4: ...e DEMO software Click on EXIT to close the program DEMO reader operation Connect Reader with PC through RS232 cable a Serial Port connection select the correct Com Port and Baud rate 9600 115200 optio...

Страница 5: ...can change the IP Address Mask code gateway e g 196 168 000 001 for Gateway need input 3 digit value section e g 000 Below error message will be found if input an incorrect format e g 0 or 00 5 click...

Страница 6: ...st select power parameter and frequency China 902 928MHz AMERICA ISM902 928MHz EUROPEAN ISM865 868MHz then click Set button as chart B Chart A chart B Antenna set and query Query working antenna click...

Страница 7: ...k ASCII option is valid read the data is ASCII code if not valid then it is hex data format Tag Write write ISO180006B tag s Data First must select one tag identify the tag first and then select selec...

Страница 8: ...t as continue tag identify the time default is 10ms then click Start button reader get to tag identify status when read the tag will show as below EPC multi tag identify success and detail record Iden...

Страница 9: ...ion bar as below EPC read success EPC GEN2 Write Select membank Membank option include KILL PWD ACCESS PWD EPC CODE TID CODE USER DATA different tag with different memeory then select address Address...

Страница 10: ...Lock Tag button if lock success the information bar will show below as below Note once the tag locked it can t unlock only can lock the bank EPC G2 KILL Select bank Bank to KILL PWD in Passeord bar in...

Отзывы: