Configuring Virtual Chassis
Quick Steps for Configuring A Virtual Chassis
OmniSwitch AOS Release 7 Network Configuration Guide
June 2013
page 9-5
Quick Steps for Configuring A Virtual Chassis
Follow the steps below for a quick tutorial on configuring two switches to operate as a Virtual Chassis.
Additional information on how to configure a Virtual Chassis is provided in the section
A switch running in standalone mode can be converted to a Virtual Chassis participant by using the CLI to
create the required
vcsetup.cfg
and
vcboot.cfg
files. The virtual chassis configuration can be kept in any
directory, including the
/flash/working
directory. The example below uses a new directory named
vc_dir
.
The minimum configuration requirements for a switch to operate in virtual chassis mode are:
•
A valid advanced license must be installed.
•
A vcsetup.cfg file must be present in the running directory and it must have, at least, a valid chassis
identifier and virtual-fabric link configured. Additionally for the switch to join a virtual chassis topol-
ogy, the virtual-fabric link must have member ports assigned to it and the underlying interfaces admin-
istratively enabled.
•
A vcboot.cfg file containing the generic virtual chassis configuration present must be present in the
running directory.
Note
: Multi-Chassis Link Aggregation cannot be configured on a switch prior to converting it to virtual
chassis mode. The MC-LAG configuration must first be removed.
Virtual Chassis Conversion
1
Enter the following on each switch using the appropriate port numbers based on the chassis physical
connections. Note that
vc_dir
is the name of the directory where the virtual chassis configuration will be
stored, it will be automatically created if it does not exist.
Chassis_1-> virtual-chassis configured-chassis-id 1
Chassis_1-> virtual-chassis vf-link 0 create
Chassis_1-> virtual-chassis vf-link 0 member-port 1/1
Chassis_1-> virtual-chassis vf-link 0 member-port 1/24
Chassis_1-> write memory
Chassis_1-> convert-configuration to vc_dir
Chassis_2-> virtual-chassis configured-chassis-id 2
Chassis_2-> virtual-chassis vf-link 0 create
Chassis_2-> virtual-chassis vf-link 0 member-port 1/1
Chassis_2-> virtual-chassis vf-link 0 member-port 1/24
Chassis_2-> write memory
Chassis_2-> convert-configuration to vc_dir
2
Reload both chassis from the newly created
vc_dir
directory:
Chassis_1-> reload from vc_dir no rollback-timeout
Chassis_2-> reload from vc_dir no rollback-timeout
Содержание os6900
Страница 28: ...Contents xxviii OmniSwitch AOS Release 7 Network Configuration Guide June 2013...
Страница 374: ...VRF Route Leak Configuring IP page 15 40 OmniSwitch AOS Release 7 Network Configuration Guide June 2013...
Страница 692: ...Policy Applications Configuring QoS page 25 84 OmniSwitch AOS Release 7 Network Configuration Guide June 2013...