background image

Page 1 of  21 

Rev. A 

 

 

 
 

 
 

User MANUAL 

 
 
 

 
 
 
 

 

InfiniSolar Inverter 3KW  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Omnikhyd Inverter 3KW  

Содержание Omnikhyd Inverter 3KW

Страница 1: ...Page 1 of 21 Rev A User MANUAL InfiniSolar Inverter 3KW Omnikhyd Inverter 3KW...

Страница 2: ...Page 2 of 21 Rev A 1 0 Revision Summary REVISION SECTION DESCRIPTION Rev A...

Страница 3: ...y accessories recommended or sold by the installer Otherwise not qualified tool may result in a risk of fire electric shock or injury to persons 5 To avoid a risk of fire and electric shock make sure...

Страница 4: ...ry or both sources simultaneously Figure 1 Working Operations 1 Line mode in Figure 2 Figure 2 When the inverter is successfully connected to the grid the inverter will operate in Line Mode Under this...

Страница 5: ...s not connected to the grid and there is no load connected PV power will charge battery directly PV Compatibility This hybrid inverter is designed to generate continuous power from three different pow...

Страница 6: ...in the data sheet of the PV modules Standard Features The Solar Inverter has the following standard features z Provides comprehensive data with easy to read graphic design in LCD display z Ground Faul...

Страница 7: ...7 of 21 Rev A 4 Equipment overview FRONT VIEW BACK VIEW A PV input connector B Grid input connector C battery input connector D AC output connector E Grounding F RS 232 Communication port B A C G H F...

Страница 8: ...ables cable length cable cross section for grid impedance requirement at the supply terminal z The recommended installation position is to be adhered to vertical 5 3 Installation Installation to the w...

Страница 9: ...tion Measure grid voltage and frequency It should be 230VAC 50HZ and single phase Open the breaker or fuse between the inverter and utility Connect AC wires as table 1 list Connectors wire suggestion...

Страница 10: ...tage of the solar inverter is 500V 5 7 Connection of battery Please ensure that he nominal battery voltage is 48Vdc first Open the breaker or fuse between the inverter and battery Connect battery wire...

Страница 11: ...nd Then the inverter will be turned on If you want to turn off the inverter simply keep pressing the OFF key continuously until the buzzer continuously sound 7 Monitoring the Inverter 7 1 LCD Informat...

Страница 12: ...on Up Press this button to select last selection or increase value Down If it s in query menu press this button to select next selection or decrease value Press this button to mute alarm in standby mo...

Страница 13: ...cy of AC input z Frequency voltage power or load percentage of AC output z Input voltage or power of PV input z Battery voltage or capability percentage z Date and time z Today or total energy generat...

Страница 14: ...21 Rev A z Input voltage or power of PV input Procedure 1 Enter Up Down Up Down Enter Enter 2 3 4 5 z Battery voltage or percentage Procedure 1 Enter Up Down Up Down Enter Enter 2 3 4 5 z Date and tim...

Страница 15: ...Rev A z Today or total energy generated Procedure z Mode of query energy generated Energy generation display of selected day Procedure LCD Display Energy generation display of selected month Procedur...

Страница 16: ...Page 16 of 21 Rev A Energy generation display of selected year Procedure 1 Enter Up Down Up Down Enter 2 3 4 5 Enter Flashes Enter Up Down Enter Esc Returns to main menu Sets year LCD Display...

Страница 17: ...y The utility icon flashes Battery is charging or discharging base on the PV input power PV module is feeding power to the grid and the inverter is not connected to battery The battery icon flashes PV...

Страница 18: ...nce Cleaning Check the following points to ensure proper operation of whole solar system at regular intervals z Ensure the inverter s inlet and outlet is clean all the time z Clean the PV modules duri...

Страница 19: ...or failure 8 High voltage on PV module 9 Power down 10 DC input over current 11 GFCI failure 12 PV insulation failure 13 Inverter DC current over 14 Line value consistent fail between MCU DSP 15 GFCI...

Страница 20: ...100 5 500 Vdc 5 0 Which is the DC voltage range that inverter can feed power to grid MPPT voltage range 250 450Vdc Shutdown voltage 70V typical Max DC Input current 13Amp Converting Power Vs PV Volta...

Страница 21: ...oad 5 for non linear load O P DC component 100mV Transient O P voltage range 220 10 Transient Time 120ms Maximum Conversion Efficiency DC AC 90 At 50 load Overload capability Grid Mode 110 Overload al...

Отзывы: