
Technical Specifications
Omnicomm LLS-Ex 5 sensors
Parameter
Value
Level measurement range
depending on the version, mm
0…700, 1000, 1500, 2000, 2500, 3000, 4000, 5000, 6000
REF-channel length, mm
- for sensors of 700, 1000 mm
length
- for sensors longer than 1500
mm
200
700
Limit of the allowed main
reduced error of level, %
± 0,5 (when working with fuel for which the calibration have
been performed, or upon filling up the tanker full in case of
changing fuel type)
Interface for measured values
output
RS-232, RS-485
Programmable interface
transmission rate, bit/s
1200, 2400, 4800, 7200, 9600, 14 400, 19 200, 38 400, 57 600,
115 200
Power supply voltage, V
5,1
Power consumption, not more
than, W
0,4
Current consumption, not more
than, mA
40
6
Technical Specifications
Содержание LLS-Ex 5
Страница 1: ...Omnicomm LLS Ex 5 Fuel Level Sensor and BIS MX Intrinsic Safety Unit User Manual 06 07 2020 ...
Страница 14: ...Omnicomm Configurator PC Fuel level is displayed without regard for filtration 14 Setting ...
Страница 21: ...Connect one Omnicomm LLS Ex 5 fuel level sensor as shown in the figure 21 Installation and Connection ...
Страница 29: ...29 Fuel level sensor installation recommendations for cylindrical fuel tanks ...
Страница 33: ...info omnicomm world com www omnicomm world com ...