Appendix H. Diagrams for Connection to Installed Terminating
Resistors
Note. Terminating resistors must be installed as close to external device/Product
connectors as possible.
External device may include a terminating resistor. In such cases it is not required to
install a terminating resistor from the external device side. Presence of a terminating
resistor in the external device is determined on the basis of the external device
documentation.
The GND power supply circuit (white wire) of BIS 20240 should be connected to the
vehicle's body or to the battery, using the BR15 galvanic isolation unit.