Appendix I. Example of Setting Offset Values and Measurement
Range
Initial data:
Fuel tank with the installed Product (Figure 43)
Fuel tank depth: 700 mm
Sensor working length: 680 mm
It is required to set the product in such a way that the fuel level is measured in
millimeters with the scale factor of 0.5 mm.
Solution:
Set measurement range value: 1,360;
Offset value: 40.
Therefore, the level value is reduced to millimeters with the scale factor of 0.5mm.