3.6.4 Ending a Batch
End a batch in progress through OMNICONNECT in one of three ways: manually through the
Batch Control screen, automatically through a timed schedule, or remotely through Modbus
writes.
Manual Batch End
To manually stop an individual batch, follow these instructions:
1.
In the Actions ribbon, click
Operate
.
2.
Expand the
Control
tree to see the
previously configured Meter Runs and
Stations under each batch category.
a. For liquid applications, go to Step 3.
b. For gas applications, go to Step 4.
When ending a batch while flow is occurring, remember that the next batch will start
immediately after you end the current one.
3.
For liquid applications:
a. To end a batch and automatically
cause a stack shift, which
automatically starts to measure the
next queued product in the sequence,
select an option in the
Batch
– Stack
Shift
list.
b. To end a batch and not automatically
shift the stack, select an option in the
Batch
– No Stack Shift
list.
c. Go to Step 5.