Increasing the Output Power, Operating Modes
101
7.3.2
2 x 32 A High Burden Mode (L-L)
2 x 0 ... 32 A (±45 A
DC
), max. 70 V
peak
, 2 x 870 VA at 25 A
The currents 1 and 2 of each group are phase-opposite.
Observe the safety instructions given in Section 7.1 on page 95 when using
this operating mode.
Figure 7-7:
Two-phase operation
2 x 32 A high burden mode
Load
1’
N
1
’
2’
N
2
’