7 |
P a g e
3
Hardware Setup
3.1
Connecting your Layer N Smart Interface
The SP-016 requires a Layer N Smart Interface to connect to your computer. Use the M12 8-Pin Connector diagram below to
connect your SP-016 to your Layer N Smart Interface.
3.2
Heat Flux Sensor Wiring Diagram
The Layer N SP-016 accepts digital pulse inputs through its M12 4-Pin connector. If you are connecting wire directly to the
SP-016, view the wiring diagrams provided below:
4
SYNC Configuration
Layer N Smart Probe products are easily configurable through SYNC configuration software. Ensure SYNC is running on your
Windows OS computer before continuing. Connect your SP-016 to your computer through your Layer N Smart Interface.
Note:
SYNC is available to download for free on the OMEGA website.
4.1
Connecting to SYNC - Automatic Detect
Once the SP-016 and Layer N Smart Interface are connected to your computer, SYNC will automatically detect it and begin
displaying temperature readings.
Note:
If you have successfully connected your SP-016 to SYNC and have readings appearing in SYNC, skip ahead to
the section
4.3 Heat Flux Interface
.
4.2
Connecting to SYNC – Manual
If SYNC does not automatically detect your device, follow these instructions to manually connect it.
Step 1:
Click on the
icon located on the top left of the SYNC interface.
Step 2:
Proceed through the Add Device Wizard and click
End Device / Probe
.
Pin
Name
Function
Pin 1
DIO 0
Discrete I/O Signal 0
Pin 2
INTR
Interrupt Signal
Pin 3
SCL
I2C Clock Signal
Pin 4
SDA
I2C Data Signal
Pin 5
Shield
Shield Ground
Pin 6
DIO 1
Discrete I/O Signal 1
Pin 7
GND
Power Ground
Pin 8
3.3VDD
Power Supply
Pin
Thermocouple
TempCO
Pin 1
TC-
Pin 2
Ther
Pin 3
Thermopile -
Pin 4
TC +
M12 8-Pin Connector
M12 5-Pin Connector