INSTRUCTIONS FOR THE INSTALLER

Electrical connection

The appliance is supplied with a standard 10 

Amp service cord terminated by a 3-pin plug for 

connection to a standard household socket. The 

electrical supply is required to power the electronic 

ignition system.

NOTE:

 It will be necessary for servicing purposes 

to disconnect the electrical power supply. The 

power point should therefore be accessible after 

the appliance is installed, as specified in the local 

wiring regulations.

TESTING APPLIANCE OPERATION

After installation the installer must fully test the 

appliance and ensure it operates correctly before 

handing it over to the customer.

GAS CONVERSIONS AND ADJUSTMENTS

Data Label

This appliance is suitable for Natural Gas and 

Universal LPG; ensure that the available gas supply 

matches the Data Label.

When converting from Natural Gas to Universal 

LPG ensure that the NG regulator is removed 

and replaced with the Test Point Assembly. An 

AGA Approved gas regulator suitable for a supply 

pressure of 2.75kPa should be part of the gas 

tank supply and the test point pressure should be 

adjusted to 2.75kPa.

Replacing the injectors

If the equipment is adjusted for a type of gas that is 

different from the one available, it is necessary to 

replace the burner injectors.

The choice of the injectors to replace must be 

made according to the table of the “technical 

characteristics” as enclosed.

Act as follows: 

 

– remove the racks and burners. 

 

– by means of a straight spanner L, unscrew 

the injectors U (fig. 7) and substitute it with the 

corresponding one. 

 

– tighten the injectors strongly. 

After changing the injectors, it is necessary to 

eliminate residual natural gas in the system. 

To do this you have to turn to the maximum 

position then press the knob of each burner and 

wait few seconds.

Adjusting the burners

The lowest flame point must always be properly 

adjusted and the flame must remain on even if 

there is an abrupt shift from the maximum to the 

minimum position.

If this is not so, it is necessary to adjust the lowest 

flame point as follows:

 

– start the burner up

 

– turn the tap up to the minimum position (small 

flame)

 

– remove the knob from the tap rod

 

– introduce a flat-tip screwdriver in the hole F of the 

tap (fig.8-8/A) and turn the by-pass screw up to 

a proper adjustment of the lowest flame point.

As regards U-LPG gas burners, the by-pass 

screw must be tightened completely.

MAINTENANCE

Maintenance Schedule

No regular maintenance is required for the hotplates 

except cleaning.

Replacing the power supply cable

If the power supply cable should be replaced, 

it is necessary to use a cable with a section of 

3x0.75mm

2

, type H05VV-F or H05RR-F, complying 

with the regulations in force.

The connection to the terminal board must be 

effected as shown in fig.9 - 9/A:

brown cable  

   L 

(phase)

blue cable  

  N  

(neutral)

green-yellow cable    (ground)

Содержание OCG63X

Страница 1: ...TALLATION AND USE OF BUILT IN HOT PLATES OCG63X OCG63FX OCG75X OCG75FX OCG90X OCG90FX omegaappliances com au Always serves you well attaccare qui copia targhetta segnaletica OCG63XB OCG63FXB OCG75XB O...

Страница 2: ...e from the manufacturer or its service agent Before carrying out the maintenance or cleaning the equipment cut off power supply and allow it cool down Make sure that air circulates around the gas equi...

Страница 3: ...ositions must be chosen between the maximum and the minimum ones never between the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the clos...

Страница 4: ...spark plugs No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean...

Страница 5: ...the electrical supply Don t use a steam cleaner for the cleaning the hob It is advisable to clean the appliance when it is cold Enamelled parts The enamelled parts must be washed with a sponge and so...

Страница 6: ...b is going to be installed on the top of a built in oven without forced cooling ventilation proper air vents must be installed to guarantee an adequate ventilation with the lower air entering with a c...

Страница 7: ...ing washer is placed between the manifold end and the flat face on the elbow The tapered thread connects to the outlet of the regulator and is sealed on the thread using approved thread sealing tape o...

Страница 8: ...ace must be made according to the table of the technical characteristics as enclosed Act as follows remove the racks and burners by means of a straight spanner L unscrew the injectors U fig 7 and subs...

Страница 9: ...9 1 2 3 4 5 6 8 7 9 9 A F OFF MAXIMUM MINIMUM 8 A F...

Страница 10: ...nnection Electrical Supply Cord 207 105 510 590 MODEL OCG63X OCG63XB OCG63FX OCG63FXB Depth of cooktop casing from benchtop surface 44 mm Gas Connection Electrical Supply Cord 270 183 750 510 2 4 1 2...

Страница 11: ...Natural 1 00 110 Adjust 6 3 3 AUXILIARY Universal LPG 2 75 52 27 3 4 Natural 1 00 80 Adjust 3 4 4 TRIPLE CROWN Universal LPG 2 75 95 60 12 0 Natural 1 00 160 Adjust 13 0 5 DOUBLE CROWN Universal LPG 2...

Страница 12: ...ktop is to be used for cooking vessels of diameter 120mm or smaller Incorrect fitment Correct fitment Examples of positioning of mini trivet MODEL OCG63X OCG63XB OCG63FX OCG63FXB MODEL OCG75X OCG75XB...

Отзывы: