background image

Device description 

  

- 6 - 

 

M-5575/0416 

 
 

IMPORTANT! 

  Use the type plate to check if the delivered unit corresponds to your order.  

  In particular, for devices with electrical components, check to see if the correct power 

supply voltage is specified. 

 

Accessories: 

  Connection cable with moulded M12x1 coupling 

socket. 

  M12x1 coupling socket as component. 

 

 

 

1.2  Intended use 

 

The magnetic inductive flow sensor FMG70B must only be used for measuring and metering 

liquids with a minimum conductivity of 50 μS/cm.

 

 

WARNING! No safety component! 

The magnetic inductive flow sensor of the series FMG70B is not safety components in 
accordance with Directive 2006-42-EC (Machine Directive).  

  Never use the FMG70B as a safety component. 

 

The operational safety of the device supplied is only guaranteed by intended use. The 
specified limits (

 § 9 "Technical data") may under no circumstances be exceeded.  

Before installing the device, check that the wetted materials of the device are compatible with 
the media being used (

 § 9.2 "Materials table"). 

 

Measuring tube empty (or partially filled). / Conductivity too low. 
The green LED may blink irregularly if the measuring tube of the FMG70B is empty or 
partially filled or if the conductivity of the fluid being used is too low. Random impulses 
will be present at the output, but they do not represent an actual flow. 

  Ensure that the measuring tube of the FMG70B is always completely filled (

 § 4.1 

"Installation instructions"). 

 

Ensure that the conductivity of the fluid is at least 50 μS/cm.

 

 

1.3  Exclusion of liability 

 

We accept no liability for any damage or malfunctions resulting from incorrect installation, in-
appropriate use of the device or failure to follow the instructions in this operating manual. 

 

 

 

 

 

 

Содержание FMG70B Series

Страница 1: ...FMG70B Series Magnetic Inductive Flow Sensor...

Страница 2: ...2 M 5575 0416...

Страница 3: ...g 13 6 2 Switching on and off 13 6 3 Measuring mode 13 7 Maintenance and cleaning 15 7 1 Return shipment to the manufacturer 15 8 Disassembly and disposal 16 9 Technical data 17 9 1 Characteristics FM...

Страница 4: ...is sign indicates dangers that cause personal injuries that can lead to health defects or cause considerable damage to property CAUTION Electric current This sign indicates dangers which could arise f...

Страница 5: ...G70B It contains the most important data the connection diagram and the arrow for the flow direction Example Fig 1 1 Delivery unpacking and accessories All units have been carefully checked for their...

Страница 6: ...d is only guaranteed by intended use The specified limits 9 Technical data may under no circumstances be exceeded Before installing the device check that the wetted materials of the device are compati...

Страница 7: ...FMG70B must hold a relevant qualification This can be based on training or relevant tuition The personnel must be aware of this operating manual and have access to it at all times The electrical conne...

Страница 8: ...ed in the middle of the measuring tube between the earthing sleeves The FMG70B does not need any moving parts to make measurements The inside of the measuring tube is completely open allowing the flui...

Страница 9: ...pment is depressurized and has cooled down SUITABLE TOOLS Use only suitable tools of the correct size 4 1 Installation instructions CAUTION Risk of malfunction due to external magnetic fields Magnetic...

Страница 10: ...OTICES Observe the flow direction indicated on the FMG70B Observe the mounting dimensions 9 5 Dimensions Select an appropriate location for installation 4 1 Installation instructions To ensure the bes...

Страница 11: ...ed power Optional wirings Depending on the version an analog output can be optionally connected Connecting cable Suitable connection cables with molded coupling socket are available in various lengths...

Страница 12: ...o not connect Connect the connecting cable according to your version and the pinout on the type plate Supply voltage FMG70B with frequency output Push Pull 1 NPN Open Collector PNP Open Collector 1 Pu...

Страница 13: ...the connected supply voltage Switch on the supply voltage The green LED lights up once for 1 s The FMG70B is ready and goes into measuring operation 6 3 Measuring mode In measuring mode the green LED...

Страница 14: ...ng and measuring mode 14 M 5575 0416 FMG70B with analog output According to the configuration of the FMG70B the analog output provides a voltage or current signal This signal is proportional to the me...

Страница 15: ...e unit before return to Omega Costs incurred due to inadequate cleaning of the device and possible costs for disposal and or personal injuries will be billed to the operating company WARNING Risk of i...

Страница 16: ...Prior to disassembly ensure that the equipment is switched off and is in a safe and de energized state the equipment is depressurized and has cooled down Disassembly Remove the electrical connectors...

Страница 17: ...se rate pulses gal optional 2 2 000 4 7 500 1 000 4 3 700 250 4 750 Resolution gal pulse optional 2 0 0005 0 26 0 0001 0 001 0 26 0 0003 0 005 0 26 0 0013 Signal shape Square wave signal duty cycle 50...

Страница 18: ...pressure 232 psi Process connection NPT male thread NPT male thread NPT male thread 1 NPT male thread The maximum ambient temperature depends on the temperature of the medium and the wiring of the FM...

Страница 19: ...Technical data Technical changes reserved 19 9 4 Temperature limits The maximum ambient temperature depends on the medium temperature and the version of the FMG70B...

Страница 20: ...Technical data 20 M 5575 0416 9 5 Dimensions FMG71B and FMG72B NPT only for FMG72B The cross section of the FMG72B does not taper to 0 16 in FMG73B...

Страница 21: ...For your notes Technical changes reserved 21 For your notes...

Страница 22: ...For your notes 22 M 5575 0416 For your notes...

Страница 23: ...Technical changes reserved 23...

Страница 24: ...24 M 5575 0416 M 5575 0416...

Отзывы: