background image

An  O ME GA Te c h n o l o g i e s  Co m p a n y

 M2107/1294

INSTRUCTION

SHEET

DP18 Series

Model DP18-RT1
True RMS Ammeter

CCD1294APC2BA

FIG. 3

A

C

E

G

F

D

B

SIGNAL INPUT
          5 Aac.

A

SPAN

OFFSET

1

10

D
C
B
A

+

-

REAR VIEW

Setpoint R1
(option)

Setpoint R2
(option)

FRONT VIEW

FIG. 2

FIG. 1

SIGNAL
INPUT

SPAN : ADJUST THE MAXIMUM READING.
OFFSET : NOT IN SERVICE

SPAN ADJUSTMENT IS ACCESSIBLE BEHIND THE LOW DOOR.

Isolated digital output

(option)

RANGE SELECTION

0.01

0.1

S1 SELECTOR

HOLD,

 latch the reading

display, while these pins
are linked

ANALOG OUTPUT
(OPTION)

POWER SUPPLY

see instrument label

150

150.0

B

400

400

G

500

500

F

600

600

E

750

750

D

1000

1000

C

1500

1500

B

2000

1999

A

CLOSE

RESOLUTION

READING

I NOMINAL

Amp.AC

Amp.AC

JUMPER

Amp.AC

Amp.AC

Amp.AC

5

5.00

F

10

10.00

C

15

15.0

B

40

40.0

G

50

50.0

F

60

60.0

E

75

75.0

D

100

100.0

C

JUMPER

Amp.AC

I NOMINAL

READING

CLOSE

RESOLUTION

B

C

SIGNAL CONDITIONER
 COMPONENTS VIEW

IC2

0.1

1

PLACE THE PLUG-IN JUMPER ON THE
SELECTOR S1, IN FUNCTION OF THE
NOMINAL CURRENT
TRANSFORMER, AND THE DECIMAL
POINT JUMPER ON THE
CORRESPONDING POSITION (FIG. 5).
TO OBTAIN THE INDICATED PERFOR-
MANCE, USE CURRENT
TRANSFORMERS CLASS 0.5 OR
BETTER

DISPLAYS . . . . . . . . . . . . . . . . . . . . . .  3       digits, 7 segment, red LED
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  0.56" (14.2 mm.)
SYMBOLS . . . . . . . . . . . . . . . . . . . . . .  1.8.8.8
DECIMAL POINTS . . . . . . . . . . . . . . . .  Selectable by jumpers
OVERRANGE INDICATION . . . . . . . . .  Display flashes 1999

INPUT CONFIGURATION . . . . . . . . . . .  Bipolar single
ZERO . . . . . . . . . . . . . . . . . . . . . . . . .  Automatic
SPAN ADJUSTMENT . . . . . . . . . . . . . .  ± 5 %

CONVERTER . . . . . . . . . . . . . . . . . . . .  Dual-slope, average value
SIGNAL INTEGRATION PERIOD . . . . .  80 ms.
READ RATE . . . . . . . . . . . . . . . . . . . .  3.12 / sec.
RANGES . . . . . . . . . . . . . . . . . . . . . . .  See table selection fig. 3
HOLD . . . . . . . . . . . . . . . . . . . . . . . . .  Optional

NOISE REJECTION NMR . . . . . . . . . . .  50 dB. 50/60 Hz.
ACCURACY . . . . . . . . . . . . . . . . . . . .  0.2 % ± 1 count
WARMUP TO RATED ACCURACY .  .  .  2  minutes
SPAN TEMPCO . . . . . . . . . . . . . . . . . .  150 ppm.
ZERO TEMPCO . . . . . . . . . . . . . . . . . .  2.5 µV/°C.

OPERATING TEMPERATURE . . . . . . .  0 to 50 °C (32 to 122 °F)
STORAGE TEMPERATURE . . . . . . . . .  -40 to 80 °C (-40 to 176 °F)
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . .  310 gr. (0.68 lb)
CASE MATERIAL . . . . . . . . . . . . . . . .  ABS, DIN 43700, black  color
STANDARD POWER . . . . . . . . . . . . . .  115 Vac. ± 10 %, 50/60 Hz.
POWER CONSUMPTION . . . . . . . . . . .  5.5 VA for AC.
ELECTRICAL CONNECTIONS . . . . . . .  Push-in cable connectors
BURN-IN . . . . . . . . . . . . . . . . . . . . . . .  24 h.

½

SPECIFICATIONS

½ 

DIGITS AC AMMETER, TRUE-RMS VALUES, WITH SELECTABLE RANGES ON THE SIGNAL CONDITIONER BY PLUG-IN JUMPERS. THE

READING CAN NOT BE MODIFIED IN ENGINEERING UNITS, UNLESS THE AMPLIFIER IS MODIFIED. THEREFORE USING THE STANDARD
AMPLIFIER THE DISPLAY WILL SHOW THE VALUES INDICATED ON THE TABLE. THE INPUT ALLOWS DIRECT CONNECTION TO A CURRENT
TRANSFORMER (CT) WITH A 5 Aac. SECONDARY, WITHOUT NEED FOR AN INTERMEDIATE STEP DOWN.