PLATINUM
TM
Series User’s Guide
37
Reference Section: Programming Mode (PRoG)
Setting
Absolute (AbSo)
Deviation (d.SP1)
Deviation (d.SP2)
AboV
>
ALR.H
>
SP1
+
ALR.H
>
SP2
+
ALR.H
bELo
<
ALR.L
<
SP1
-
ALR.L
<
SP2
-
ALR.L
HI.Lo.
<
ALR.L
or >
ALR.H
<
SP1
-
ALR.L
or >
SP1
+
ALR.H
<
SP2
-
ALR.L
or >
SP2
+
ALR.H
bANd
>
ALR.L
and <
ALR.H
>
SP1
-
ALR.L
and <
SP1
+
ALR.H
>
SP2
-
ALR.L
and <
SP2
+
ALR.H
Table 5.1 – Alarm Range Option Comparison
Absolute Mode (AbSo)
Deviation Mode (dEVI)
Figure 5.1 – Alarm Range Option Diagram
5.3.2
Absolute or Deviation Alarm (PRoG > ALM.1, ALM.2 > tyPE >
Ab.dV)
Select the Absolute or Deviation Alarm (
Ab.dV
) parameter.
Navigate to the correct setting. Settings and subsettings include the following:
•
AbSo
– Alarm is triggered using calculations based on the absolute values of
ALR.H
or
ALR.L
used as specified by the
tyPE
parameter
•
d.SP1
– Alarm is triggered using calculations based on values relative to
SP1
as
specified by the
tyPE
parameter
•
d.SP2
– Alarm is triggered using calculations based on values relative to
SP2
as
specified by the
tyPE
parameter
Select the desired setting.
5.3.3
Alarm High Reference (PRoG > ALM.1, ALM.2 > tyPE >
ALR.H)
Select the Alarm High Reference (
ALR.H
) parameter.
Set the Alarm High Reference value.
Confirm the value.
5.3.4
Alarm Low Reference (PRoG > ALM.1, ALM.2 > tyPE > ALR.L)
Select the Alarm Low Reference (
ALR.L
) parameter.
Set the Alarm Low Reference value.
Confirm the value.
bANd
AboV
,
HI.Lo.
bELo
,
HI.Lo.
Higher
Lower
ALR.L
ALR.H
(SP2 has the same
alarm options.)
SP1
SP2
bANd
Higher
Lower
ALR.L
bELo, HI.Lo.
ALR.H
AboV, HI.Lo.
Omega Engineering | www.omega.com