User’s Guide

HH502

Digital Thermometer

Shop online at

Содержание HH502

Страница 1: ...omega com e mail info omega com For latest product manuals omegamanual info User sGuide HH502 Digital Thermometer Shop online at ...

Страница 2: ...ingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Servicing Europe U S A and Canada Sales Service 1 800 826 6342 1 800 TC OMEGA Customer Service 1 800 622 2378 1 800 622 BEST Engineering Service 1 800 872 9436 1 800 USA WHEN U S A ISO 9001 Certified OMEGA Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 USA Toll Free 1 800 826...

Страница 3: ...rmocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector INTRODUCTION This instrument is a 4 digit compact sized portable digital thermometer designed to use external K type and J type thermocouples as temperature sensor TemperatureindicationfollowsReferenceTemperature VoltageTables N I S T Monograph 175 Revised to ITS 90 for K type and J type thermo couple...

Страница 4: ... 0 05 rdg 0 3 C 50 C to 1370 C 0 05 rdg 0 7 C 50 C to 200 C 0 05 rdg 0 6 F 58 F to 2498 F 0 05 rdg 1 4 F 58 F to 328 F TemperatureCoefficient 0 1timestheapplicableaccuracyspecificationper C from 0 C to 18 C and 28 C to 50 C 32 F to 64 F and 82 F to 122 F Input Protection 24V dc or 24V ac rms maximum input voltage on any combination of input pins Maximum Differential Common Mode Voltage Maximum Vol...

Страница 5: ...0 R H GENERAL Display 4 digit liquid crystal display LCD with maximum reading of 19999 Overload is display Battery Standard 9V battery Battery Life 100 hours typical Auto power off The meter key switch inactive for more than 30 minutes press power key to resume operation Dimensions 192mm H x 91mm W x 52 5mm D Weight 365g ...

Страница 6: ...n the thermometer was last turned off To change the temperature scale press the C F key HOLD Mode only Main display Pressing the HOLD key to enter the Data Hold mode the HOLD annun ciator is displayed When HOLD mode is selected the thermometer held the present readings and stops all further measurements Pressing the HOLD key again to cancel HOLD mode causing thermometer to resume taking measuremen...

Страница 7: ... selected T1 When the thermometer is turned on it is set to the type selected that was in use when the thermometer was last turned off MIN MAX with Time record Mode only Main display Press MIN MAX key to enter the MIN MAX Recording mode displays the Maximum reading with time Minimum reading with time and Average reading stored in record mode In the this mode the automatic power off feature is disa...

Страница 8: ... REL Relative mode only Main display Pressing REL key to enter the Relative mode zero the display and store the displayed Reading as a reference value and annunciator REL is displayed Press REL key again to exit the relative mode The relative value can also be entered by the user See SET mode later in this manual When the desired Relative value has been entered press REL key to enter the Relative ...

Страница 9: ...rlay ENTER key stored the relative value enter Time set mode 2 Time set mode Press ENTER key can escape Time set mode is displayed in second and third display Time hours minutes seconds value is entered via overlay numbers then press overlay ENTER key Time start from set time value enter Hi Lo Limits value set mode 3 Hi Limit value set mode is displayed Press ENTER key can escape Hi Limit value se...

Страница 10: ...lternate of thermocouple by second display K J key switch K J T2 Input thermocouple type select second display The K J key switch the T2 input selects the K type or J type thermocouple as input when second display input selected T2 When the thermometer is turned on it is set to the type selected that was in use when the thermometer was last turned off Hi Lo Limits mode only Main display Press Hi L...

Страница 11: ...the thermometer before removing the cover Battery Replacement Power is supplied by a 9 volt transistor battery The appears on the LCD display when replacement is needed To replace the battery remove the two screws from the back of the meter and lift off the battery cover Remove the battery from battery contacts ...

Страница 12: ... 10 times greater than the measured meter Step 1 Short the J3 with jumper Step 2 Apply 65 mV to the T1 input from Volts Calibrator and wait till the reading becomes stable then press the SET key until the display shows 0 1 Step 3 Apply Type K 0 C to the input T2 and wait till the reading becomes stable then press the SET key until the meter shuts off by itself Step 4 Remove the jumper from J3 ...

Страница 13: ...11 NOTES ...

Страница 14: ...12 NOTES ...

Страница 15: ...oper specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triacs OMEGA is pleased to offer suggestions on the use of its various products However OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result f...

Страница 16: ...tors 䡺 Turbine Paddlewheel Systems 䡺 Totalizers Batch Controllers pH CONDUCTIVITY 䡺 pH Electrodes Testers Accessories 䡺 Benchtop Laboratory Meters 䡺 Controllers Calibrators Simulators Pumps 䡺 Industrial pH Conductivity Equipment DATA ACQUISITION 䡺 Data Acquisition Engineering Software 䡺 Communications Based Acquisition Systems 䡺 Plug in Cards for Apple IBM Compatibles 䡺 Datalogging Systems 䡺 Recor...