parts breakdown

Model IC-Cn-0219s 

47484

Item No. Description

Position

Item No. Description

Position

Item No. Description

Position

AC886

Display Panel for 47484

1

AK073

Capillary for 47484

13

AC885

PC Board for 47484

25

AK038

Display Panel Bracket for Vertical Type 

for 47484

2

AF020

Ice Bin Drain Pipe for 47484

14

AK076

Compressor NUY80RR for 47484

26

AK066

Front Ventilation Window for 47484

3

AK054

Inlet Valve for 47484

15

AK060

LED Lamp Reed Tube Magnetic Switch 

for 47484

27

AK067

Door Panel Assembly - Black Gray for 

47484

4

AC881

Defrost Valve Body for 47484

16

AK052

Gas-Liquid Separator for 47484

28

AK068

Door Frame Assembly - Black Gray for 

47484

5

AC882

Defrost Valve Coil for 47484

17

AK077

Filter Right Card Slot for 47484

29

AK044

Cold Light for 47484

6

AK053

Silicone Hose for 47484

18

AK078

Filter Left Card Slot for 47484

30

AK069

Sink-160 for 47484

7

AK058

Dry Filter for 47484

19

AK079

Ventilation Window Filter for 47484

31

AK070

Skateboard for 47484

8

AK055

Fan for 47484

20

AK062

Vertical Type Machine Display Board 

for 47484

32

AK071

Evaporator-91 for 47484

9

AC874

Condensation Sensor for 47484

21

AK063

Control Panel Labeled-31 for 47484

33

AK072

Sprinkler Tube Assembly for 47484

10

AK074

Fan Blades for 47484

22

AK080

Outer Door Panel for 47484

34

AK047

Ice Full Sensor - Hall Type for 47484

11

AK075

Condenser for 47484

23

AK065

Foot Block for 47484

35

AK050

Pump Assembly for 47484

12

AK059

Foot Body for 47484

24

Содержание IC-CN-0089S

Страница 1: ... 07 06 2023 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Ice Makers Model IC CN 0089S 0129S 0219S 0289S 0329 0529 Items 47773 47483 47484 47774 47485 46452 Instruction Manual ...

Страница 2: ...aimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Registration Model IC CN 0089S Model IC CN 0129S Model IC CN 0219S Model IC CN 0289S Model IC CN 0329 Model IC CN 0529 ...

Страница 3: ...antía por fugas de agua queda anulada si la almohadilla absorbente no se reemplaza cada seis meses y si la temperatura ambiente supera los 75 F y el 55 de humedad relativa y el desagüe del aparato no está conectado directamente al desagüe del piso Omcan n est pas responsable des dommages dus aux fuites d eau La garantie pour les fuites d eau est annulée si le tampon absorbant n est pas remplacé to...

Страница 4: ...utmost importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication et distribution Companie Limité et Food Machinery d Amerique dba Omcan et Omcan Inc ne sont pas responsables de tout dommage ou blessure causé du fait que toute personne ait utilisé cet équipemen...

Страница 5: ...na mientras esta en el funcionamiento REVISE EL PAQUETE A SU LLEGADA Tras la recepcion de un envio Omcan favor inspeccionar daños externos Si no hay daños evidentes en el empaque exterior Habra el carton para asegurararse que todos los articulos solicitados ésten dentro de la caja y no encuentre daños ocultos en la máquina Si el paquete ha sufrido un manejo de poco cuidado golpes o daños visible o...

Страница 6: ...s a hazardous voltage There is a risk of electric shock This label indicates a hazardous voltage There is a risk of electric shock This label indicates rotating components inside There is a risk of serious mechanical injury This label indicates a flammable foaming agent Cyclopentane used There is a risk of fire ...

Страница 7: ... result in explosion or fire Do not store any sundries or freeze any food in the ice bin Keep the ice scoop clean The ice machine must be placed on the floor sufficient to supports its weight Insufficient base may cause the equipment fall over and cause injury There should be sufficient ventilation space around the ice machine Keep good ventilation Only the power supply specified on the machine na...

Страница 8: ...milar occasions The kitchen area of a store office or other workplace Farm hotel car hotel and restaurant Catering and similar non retail occasions This ice machine is not intended for used at home RESIDENTIAL USERS vendor assumes no liability for parts or labor coverage for component failure or other damages resulting from installation in non commercial or residential applications The right is re...

Страница 9: ... 835mm 22 8 x 26 4 x 32 9 580 x 670 x 835mm 30 7 x 29 3 x 35 4 780 x 745 x 900mm Item Number 47773 47483 47484 Model IC CN 0289S IC CN 0329 IC CN 0529 Power 726 W 790 W 1113 W Electrical 110 120V 60Hz 1 Bin Capacity 79 4 lbs 36 kgs 275 6 lbs 125 kgs 374 8 lbs 170 kgs Production per Day 280 lbs 127 kgs 352 7 lbs 160 kgs 496 lbs 225 kgs Ice Shape Cube Max Ambient Temp Rating 24 C 75 F Condenser Unit...

Страница 10: ...n it For air cooled unit it requires good ventilation Therefore the front and rear of the ice maker must have ventilation space of more than 20 30 cm 5 The bottom of the ice machine is equipped with adjustable legs for level adjustment and floor cleaning 6 Connect the machine s inlet water filter and water pipe referring to the schematic diagram of installation if the installation site is already ...

Страница 11: ...l take Ice cube can be properly defrosted from the machine Operation Instruction Startup after proper installation connect the water source and turn on the power supply the machine will start working Please confirm that the machine is operating normally when you turn it on for the first time Note in case of thunderstorm or not in use for a long time please disconnect the power and water source Sel...

Страница 12: ...k the button or on the panel to adjust the thickness of ice cube Note by clicking the or button one time the ice making time is extended or shortened by 1 5 minutes 4 Cleaning during the normal operation hold the cleaning button for 3 seconds to enter the cleaning process During the entire cleaning process cleaning agents and disinfectants need to be put into the water trough When the clean proces...

Страница 13: ...ent and then wiped clean If necessary use commercial stainless steel cleaners and polishes Note stainless steel may rust without proper maintenance Inlet water filter The filter element should be inspected regularly It is recommended to replace filter element every month to every 3 months Interior cleaning The inside of the ice storage bin can be washed directly with water pipes Note check and con...

Страница 14: ...ton again the ice maker will do auto sterilizing for about 15 minutes Please do spray sterilizing to the evaporator at the mean time to insure a complete sterilizing When finished the ice maker will get into rinsing process the process will take about 5 minutes and do 5 cycles rinsing The ice maker will get back to do ice making as soon as the clean process end Please throw away the next 5 batches...

Страница 15: ... correct the fan Ice defrost abnormal Ambient temperature too low Normal working temperature range of 24 C Defrost valve does not start normally Check and correct the defrosting valve Ice thickness too thin or too thick Check and correct ice thickness setting Poor transparency of ice cubes ice cubes too thin or incomplete Ice thickness too thin Check and correct ice thickness setting Water pressur...

Страница 16: ...is not leveled Level the ice machine Error Codes Code Comments Work Mode E01 Water curtain or ice full switch fault Sleeping mode and recover after the water curtain is reset E03 Ice harvest overtime Sleeping mode E04 High temp fault Sleeping mode E05 Water shortage fault Sleeping mode and retry every 30 mins E06 Over pressure fault Sleeping mode E07 Cond temp sensor open circuit fault Keep workin...

Страница 17: ...17 Parts Breakdown Model IC CN 0089S 47773 ...

Страница 18: ...47773 15 AN304 Spray Pipe Assembly for 47773 26 AN283 Filter Mesh Platemetal Frame for 47773 5 AN294 Exhaust Pipe Assembly for 47773 16 AN305 Evaporator for 47773 27 AN284 Door Panel Assembly Black Gray Color for 47773 6 AN295 Defrost Valve Coil for 47773 17 AN306 Ice Skating Board for 47773 28 AN285 Door Frame Assembly Black Gray Color for 47773 7 AN296 Water Inlet Valve for 47773 18 AN307 Cold L...

Страница 19: ...19 Parts Breakdown Model IC CN 0129S 47483 ...

Страница 20: ...17 AC885 PC Board for 47483 29 AK041 Filter Left Card Slot for 47483 6 AK053 Silicone Hose for 47483 18 AK060 LED Lamp Reed Tube Magnetic Switch for 47483 30 AK042 Filter Right Card Slot for 47483 7 AC881 Defrost Valve Body for 47483 19 AK061 Compressor DLE6 5CN for 47483 31 AK043 Door Frame Assembly Black Gray for 47483 8 AC882 Defrost Valve Coil for 47483 20 AK062 Vertical Type Machine Display B...

Страница 21: ...21 Model IC CN 0219S 47484 Parts Breakdown ...

Страница 22: ... Frame Assembly Black Gray for 47484 5 AC882 Defrost Valve Coil for 47484 17 AK077 Filter Right Card Slot for 47484 29 AK044 Cold Light for 47484 6 AK053 Silicone Hose for 47484 18 AK078 Filter Left Card Slot for 47484 30 AK069 Sink 160 for 47484 7 AK058 Dry Filter for 47484 19 AK079 Ventilation Window Filter for 47484 31 AK070 Skateboard for 47484 8 AK055 Fan for 47484 20 AK062 Vertical Type Mach...

Страница 23: ...23 Model IC CN 0289S 47774 Parts Breakdown ...

Страница 24: ...Pipe Assembly for 47774 14 AN326 Water Sink for 47774 24 AN312 Filter Net Assembly for 47774 5 AN319 Defrost Valve Coil for 47774 15 AN307 Cold LED Light 66481554 for 47774 25 AN313 Condenser for 47774 6 AN297 Feet Assembly for 47774 16 AN327 Door Frame Assembly Black Gray Color for 47774 26 AN314 Fan Blades for 47774 7 AN320 Base Plate for 47774 17 AN328 Door Panel Assembly Black Gray Color for 4...

Страница 25: ...25 Model IC CN 0329 47485 Parts Breakdown ...

Страница 26: ...7485 4 AC884 Ventilation Window Filter for 47485 14 AC894 Water Pump for 47485 24 AC875 Inlet Valve for 47485 5 AC885 PC Board for 47485 15 AC895 Water Level Water Temperature Sensor for 47485 25 AC876 Drain Valve for 47485 6 AC886 Display Panel for 47485 16 AK090 Sink Pump Fixing Plate for 47485 26 AK084 Compressor R290 for 47485 7 AC887 Electrical Control Fixing Plate for 47485 17 AK091 Sink for...

Страница 27: ...27 Model IC CN 0529 46452 Parts Breakdown ...

Страница 28: ...9 47485 Model IC CN 0529 46452 Item No Description Position Item No Description Position Item No Description Position AC872 Microchannel Condenser for 46452 1 AC882 Defrost Valve Coil for 46452 11 AC892 Ice Full Sensor for 46452 21 AC873 Fan for 46452 2 AC883 Plastic Window Filter for 46452 12 AC893 Upper Water Pipe for 46452 22 AC874 Condensation Sensor for 46452 3 AC884 Ventilation Window Filter...

Страница 29: ...29 Model IC CN 0089S 47773 Model IC CN 0289S 47774 Electrical Schematics ...

Страница 30: ...30 Model IC CN 0129S 47483 Model IC CN 0219S 47484 Model IC CN 0329 47485 Model IC CN 0529 46452 Electrical Schematics ...

Страница 31: ...gister online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Information Name Company Name Address Telephone City Province or State Postal or Zip Email Address Country Type of Company Restaurant Bakery Deli Dealer from which Purchased Butcher Supermarket Catere...

Страница 32: ...s relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Amérique du Nord Europe Asie et Amérique du Sud nous travaillons continuellement à améliorer et développer l entreprise Nous nous efforçons d offrir à nos clients une valeur exceptionnelle grâce à nos ventes locales qualifiées et des représentants de service qui offrent un accès facile à plus de 6500 produ...

Отзывы: