12
Maintenance
CLEANING INSTRUCTIONS
CAUTION
• DO NOT use any abrasive or flammable cleaning fluids.
•
DO NOT hose down, immerse or pressure wash any part of the hot plate, excluding the catch tray.
• NEVER use a scrubber pad (on all exterior surfaces, except the hot plate plate), steel wool or abrasive
material, or cleaners containing chlorine, iodine and ammonia or bromine chemicals as these will
deteriorate the stainless steel and shorten the life of the unit.
IF CLEANING ALL THE HOT PLATE’S SURFACES, THE MAIN GAS VALVE MUST BE SWITCHED
TO THE CLOSED POSITION. AFTER CLEANING, THE GAS LINE CAN BE SWITCHED BACK TO
THE OPEN POSITION. PLEASE FOLLOW THE LIGHTING INSTRUCTIONS IN THIS MANUAL TO
RELIGHT THE HOT PLATE’S PILOT LIGHTS AS NEEDED.
RECOMMENDED CLEANING
It takes very little time and effort to keep the hot plate attractive and performing at top efficiency. Wait until the
hot plate is cool after the unit has been turned off. Please follow the cleaning steps below:
Part
Required Action
Frequency
Grates
Wash with soap and water.
Daily
Body
Use a clean cloth and a non-abrasive cleaner to clean the stainless
steel body of the hot plate. Wipe the polished areas with a soft cloth.
Daily
Controls
Unit should be turned off when not in use. It is recommended that the
unit be disconnected from the gas supply by closing the main gas valve.
Use a clean cloth to wipe any down controls and/or knobs.
Daily
Catch Tray
Once the unit has cooled, remove the catch tray and discard the waste,
debris and crumbs. CAUTION: If the catch tray is permitted to fill too
high, debris is likely to accumulate under the unit. The catch tray/drawer
is removed by pulling forward. USE CAUTION WHEN REMOVING!
Per Use or at
least Daily
Burner Air
Shutter
Openings
Main burner ports must be kept clean. Close the gas valve to the unit
shutting of the gas and extinguishing the pilot light. Clean in place with
a wire brush or clean gas ports with a sharp-pointed metal instrument to
insure open ports or the burners may be removed and washed in soapy
water for 15-20 minutes.
As needed
Regulator
Make sure the vent opening is open and not blocked in any way. Failure
to do so will cause variations in pressure. Your unit will not function as
well and it could shorten the life of the product.
Monthly