olympia electronics WEATHER LIGHT Series Скачать руководство пользователя страница 1

Thank  you  for  purchasing  this  product  of 
O l y m p i a   E l e c t r o n i c s .   A   E u r o p e a n  
manufacturer.

GENERAL

These  luminaires  are  used  in  places  where 
emergency luminaires are needed.
E a c h   l u m i n a i r e   m u s t   b e   p e r m a n e n t l y  
connected to mains power supply. In normal 
operation  the  battery  is  charging  and  the  2 
yellow  LED’s  light  in  the  screen  (see  step  4 
on  page  2).  In    case    of    a    mains    power   
supply  failure    the    luminaire    will    light  the 
led  strip    automatically  in  emergency  mode.   
When the  mains  power  supply  is  restored 
the device turns to normal operation.

ΑΤΤΕΝΤΙΟΝ!!!

1.  Operations  for  installation,  maintainance 
or  testing  must  be  done  by  authorized 
personel only.

2.  The  device  must  be  connected  to  the 
mains  power  supply  thru  a  fuse  dependent 
by the total amount of the line’s  power load.

3.  It  is  sugested  to  check  every  month  the 
indication  LED  for  battery  charging,  and  by 
pushing the TEST button (see the paragraph 
9 on page 2), to check the emergency cirquit. 
The  lamp  should  light  as  long  as  the  TEST 
button  is  pressed

.  In  the  opposite  condition 

contact the installer. 

4. It is sugested to check every 6 months the 
minimum autononous duration by 
disconnecting the mains power supply. Count 
the time that  the led strip lights and in case of 
less time than the minimum autonomous 
duration the battery must be replaced. If the 
measured time is considerably less than the 
minimum autonomous duration 

 The replacement of the battery and 

the light source must be done using parts of 
the same type, by the manufacturer or by a 
competent person.

t  i

  in  battery  recycling 

points. Do not incinerate.

contact the 

installer.

5. In case of inactive use for a period greater 
than  2  months,  disconnect  the  battery  by 
pulling out the battery’s connector. 

6. 

I

s  not  allowed  to  discard  batteries  in 

to  common  trash  bins,  they  must  be 
discarded  only 

INSTALLATION

To  install  the  luminaire  follow  the  installation 
instructions οn page 2.

NOTE:

 LED= Light Emitting Diode

LABELING EXPLANATION:
X: Self contained
0: Non Maintained
A: Including test device 
*90: 90min duration
180: 180min duration

‘’ WEATHER LIGHT ‘’ SERIES FOR NON-MAINTAINED EMERGENCY LUMINAIRES

Page 1 from 2

923936006_23_011

High Quality European based Manufacturers

220-240V AC/50-60Hz

Bayblent FR3010, transparent  polycarbonate

TECHNICAL CHARACTERISTICS

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY

EXTERNAL DIMENSIONS 

CONSTRUCTION MATERIALS 

TYPICAL WEIGHT

GUARANTEE 

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-Cd)

CHARGING TIME

INDICATIONS - CONTROLS

BATTERY PROTECTION

MINIMUM AUTONOMOUS DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

EMERGENCY ILLUMINATION

ILLUMINATION SOURCE 

180min

90min

24h

Charge indication LED, TEST button

From overcharge and full discharge

  300lm 

  300lm 

  450lm 

  415lm 

  4 power LED’s 

  4 power LED’s 

  6 power LED’s 

  6 power LED’s 

0 to 40  C

o

Up to 95% 

3 years (1 year for the battery)

363 x 145 x 73 mm

4.8V/1.5Ah

4.8V/3Ah

4.8V/4Ah(Ni-MH)

950gr.

980gr.

1020gr.

EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

IP 65

4,8VA

5,5VA

4VA

 

GR-935/6P GR-936/4P GR-936/6P   

 GR-935/4P

Отзывы: