GENERAL

o

These devices are used indoors 

(

ta 40 C

)

 

in 

places  where  emergency  luminaires  are 
needed.  The  luminaires

 

GR-290  and  GR-

292  are  suitable  for  corridors  lighting  and 
the

 

GR-291  and  GR-293  for  open  area 

lighting

.

  Each  device  must  be  permanently 

connected  to  mains  power  supply

.

  In 

normal operation the battery is charging. In 
case    of  a  mains  power  supply  failure    the 
device  will  light  the  illumination  led 
automatically  in  emergency  mode.  When 
the    mains    power    supply  is  restored  the 
device turns to normal operation.

INSTALLATION

To install the luminaire follow the installation 
instructions 

ο

n page 2.

Battery Charging

The 

battery 

charging 

is 

completely 

controlled

In  this  case,  is

 

achieved  the 

perfect    battery  maintenance 

as  well  as 

the  elongation  of  its  duration

When  the 

battery  has  completely  charged

it  charges 

with a maintenance current.

Battery Cut-off

The  device 

enters  this  mode  when  the 

mains  power  supply  fails

 

and  battery  has 

lost  its  energy

During  this  operation  the 

device  enters  the  idle  state

 

and  battery 

consumption  is  negligible,  in  order  to  be 
protected from deep discharge.

Manual

 Test

This  test  can  be  done  by  pushing  the  test 
button. The  light  source  and  the  emergency 
circuit  of  the  device  is  monitored.  The 
manual  test  can  be  conducted  only  if  the 
main  power  supply  and  the  battery  is 
connected.  During  this  test  period  all 
indication LEDs are OFF. 

Automatic Operational Test

This  test  includes  all  the  operations  that 
provide  the  manual  test  and  is  conducted 
automatically  every  15  days.  In  order  to  be 
performed,  the  mains  power  supply  and  the 
battery should be connected.        

Automatic Autonomous Test

The 

Automatic 

Autonomous 

Test 

is 

conducted  and  measures  the  device’s  back 
up  operation  and  emergency  duration.  The 
BATTERY  FAULT  LED  blinks  during    the 
measurement,  indicating  this  process  to  the 
user.  This  test  is  conducted  automatically 
every  six  months

In  order  to  be  performed, 

the  mains  power  supply  and  the  battery 
should  be  connected  and  fully  charged

If 

NON MAINTAINED SELF TESTING SPOT LIGHT 

EMERGENCY LUMINAIRES WITH 1 WHITE POWER LED

OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL

EXTERNAL DIMENSION
WEIGHT

GUARANTEE

OPERATION VOLTAGE

MAXIMUM POWER CONSUMPTION
BATTERY (Ni-MH)

CHARGE TIME

INDICATIONS - CONTROLS

BATTERY PROTECTION

MINIMUM DURATION

DEGREES OF COVER PROTECTION

PRODUCED IN ACCORDANCE WITH

EMERGENCY ILLUMINATION

LIGHT SOURCE

220-240V AC / 50-60Hz

3 hours

1.5 hour

24 hours

Deep discharge and overcharge protection

IP40

4.8V/1.2Ah

  270lm 

  160lm 

  1 white

 

power LED

o

5 to 40  C

Up to 95% 

ABS/PC, PC

3 years

 (1 

year for the battery

)

4

35

gr.

Ø125 x 65 mm

EN 60598-1, EN 60598-2-22

, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3

Charge, lamp fault, battery fault

TEST button

 GR-29

0

 GR-291

 GR-292

 GR-293

3.7W / 4.1 VA

TECHNICAL CHARACTERISTICS

 

(for LED MODULE specifications see page 4)