15
5.13
- Water Unit (Optional)
It offers the professional a point with water and drain, the water
unit is swivle in 90º allowing approach or removal of the patient. It has
junction box (7) for the hoses of water and sewage (9), and electrical
connection, making available socket (8) protected with fuse of 10 A.
In the water unit can be provided cup filler (3) and instrument
holder (6) such as Venturi saliva ejector, high power Vórtice saliva
ejector, vacuum pump adapter and 3-syringe way.
To obtain water in the spitton bowl (5): open the register (1).
To obtain water in the cup filler (3): press the button (2).
The water spouts (3 and 4) are detachable for ease of cleaning,
the water spout of the tub (4) being adjustable to direct the flow of
water in the spittoon bowl (5).
5.13.1
- 3-Way Syringe (Optional)
The 3-Way Syringe has three functions: water jet, air jet, and
spray jet.
Before beginning the use of the 3-way syringe (5), connect the
syringe tip (3) by pressing the locking ring (4) into the correct fit.
To emit air jet: press the air button (1).
To emit water jet: press the water button (2).
To emit spray jet: press simultaneously the air and water buttons
(1 and 2).
5.13.2
- Venturi Saliva Ejector
Developed for saliva ejection, the Venturi ejector has cannula
adapters (1 and 4) for fitting disposable cannulas or autoclavable metal
cannulas. It also has a solid debris filter (5) that prevents them from being sent
to the sewage system.
To activate the suction: remove the ejector (2) from the holder (3).
To deactivate the suction: place the ejector (2) in its holder (3).
The cannula adapters (1 and 4) is removable for cleaning.
The ejector has a cannula adpters for
6.5 mm (1) or
9.5 mm (4).
For proper functioning of this device it is necessary that the solid debris
filter (5) is clean and the drain to the sewage system is properly installed and
with proper inclination.
Note: the cannulas and the dental compressor do not come with the Venturi ejector.
5.13.3
- High Power Vórtice Saliva Ejector (Optional)
The Vórtice ejector is a device that uses the Venturi
saliva ejector system, but its volume capacity is superior to
that of the Venturi, reaching up to 385 mm/Hg.
It may be used for suctioning in minor surgical and
prophylaxis procedures.
Before start the operation with the vortex ejector (2), insert the cannula into the adapter (3).
To enable/disable suction for Vórtice ejector (2): use the On/Off Vórtice saliva ejector button (1) on
the pedal.
The cannula adapter (3) is removable for cleaning.
Содержание PERFORMANCE TABLE
Страница 1: ......
Страница 2: ......
Страница 24: ...24 11 Dimensional...
Страница 25: ...25 12 Simbology According to IEC 60601 1 and IEC 60878 standards...
Страница 35: ...35...
Страница 37: ......
Страница 38: ......
Страница 60: ...24 11 Dimensional...
Страница 61: ...25 12 Simbologia La simbolog a est en conformidad con las normas IEC 60601 1 y IEC 60878...
Страница 71: ...35...