background image

 

240005126 Rev A 10/27/2005 

28

PARTS LISTING: HIGHBOY MODEL: HTL 100C 

 

 

 

 

Ref. No.  Description 

 

HTL 100C 

Part No. 

 

 

 

 

Right Side Panel Assembly 

 

28456L 

Left Side Panel Assembly 

 

28457L 

3 Rear 

Panel 

 

26209L 

Blower Division Assembly 

 

28455 

5 Base 

Panel 

 

26216 

Inner Front Panel 

 

28428 

Blower Access Panel 

 

29122L 

 

Door Handle – P2-41 

 

27368 

8 Top 

Panel 

 

21437L 

Heat Exchanger Assembly 

 

26569 

10 

Combustion Chamber Retainer Bracket 

 

4141185A 

11 

Replacement Combustion Chamber 

 

8823B1 

12 

Oil Burner Mounting Plate Assembly 

 

29873 

 

Inspection Door Gasket 

 

29871 

13 

Flue Collector Assembly 

 

28306 

15 Pouch 

Gasket 

 

28645 

16 

Flue Collar Gasket (2 per unit) 

 

21994 

17 

Radiator Cleanout Cover (2 per unit) 

 

1061A 

18 

Casing Cleanout Cover (2 per unit) 

 

3011325A 

19 

Filter Frame 16” X 25” 

 

18020 

20 

Filter Frame End Support 

 

5592B2 

21 

Filter 16” X 25” Permanent 

 

2180023 

22 Junction 

Box 

 

21318 

23 

Upper Door Panel 

 

21338L 

 Logo 

Bezel 

 

28479 

 Logo 

Label 

 

28563 

24 

Fan & Limit L6064A1003B 11” Set @ 210º F (HTL C only) 

 

18121 

25 

Wire Harness, Fan & Limit 

 

29422 

26 

Wire Harness, Blower 

 

26591 

27 

Fan Center, 40 va, SPDT, 57-01V18BC4E231 

 

27740 

 Replacement 

Relay 

 

27767 

28 

Draft Regulator 

 

12240 (6”) 

29 

Oil Burner Assembly, Beckett AF65XN 

 

29593 

 

Burner Motor 1/7 HP 3450 RPM PSC 

 

29689 

 

Beckett Clean-cut Oil Pump A2EA6520 

 

29688 

 

Solid State Ignitor FRANCE 10SAY-01 

 

29522 

 

Primary Combustion Control R7184B 

 

29664 

 

Air Tube Combination AF65XN (HTL C only) 

 

11986 

 

Flame Retention Head  

 

11961 (F3) 

 

Nozzle, .85/80ºA  (HTL-100C only) 

 

2100036 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Airco HTL Series

Страница 1: ...naces HTL Up Flow Model ALL INSTALLATIONS MUST MEET ALL LOCAL PROVINCIAL STATE AND FEDERAL CODES WHICH MAY DIFFER FROM THIS MANUAL ECR International Limited OLSEN Division Read this complete manual be...

Страница 2: ...ALLATION 7 14 OIL FILTER 7 15 OIL BURNER NOZZLES 7 16 OIL BURNER ADJUSTMENT 7 17 BURNER ELECTRODES 7 18 BURNER PRIMARY SAFETY CONTROL 7 19 COMBUSTION CHAMBER 7 20 CIRCULATING AIR BLOWER 8 21 MAINTENAN...

Страница 3: ...uitable for local conditions provided the results obtained are in substantial agreement with and not less than those obtained using the procedure described in the manual In the United States Manual J...

Страница 4: ...ey openings should be closed Chimneys must conform to local provincial or state codes or in the absence of local regulations to the requirements of the National Building Code NOTE THE FURNACE IS APPRO...

Страница 5: ...supplied wire harness Similar to the rear breach units connect end of harness with eyelet connectors to the safety switch and push the heyco bushing in place to secure the wires to the WMO 1 control R...

Страница 6: ...uld be wired to a separate and dedicated circuit in the main electrical panel however accessory equipment such as electronic air cleaners and humidifiers may be included on the furnace circuit Althoug...

Страница 7: ...an insulator and impairs good heat transfer Stack temperature will increase and the overall efficiency will decrease As a means of avoiding this problem it is advisable to adjust the air supply to pr...

Страница 8: ...ower speed wires as a source of power to accessories as electronic air cleaners and humidifier transformers unless it is certain that only one motor speed will be used The unused motor taps auto gener...

Страница 9: ...burner manufacturer See oil burner manufacturer s instructions supplied with furnace or burner It is advisable to change the oil burner nozzle and oil filter on an annual basis The venting system shou...

Страница 10: ...NOT ATTEMPT TO START THE BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN THE FURNACE IS FULL OF VAPOUR OR WHEN THE COMBUSTION CHAMBER IS VERY HOT NEVER BURN GARBAGE OR PAPER IN THE FURNACE AND NEVER LEAV...

Страница 11: ...to the nozzle face is increased to 1 3 8 inches A 3 START UP The furnace should be operated for a minimum of 15 minutes to reach steady state conditions before fine tuning combustion The warm up time...

Страница 12: ...1 HP 1200 1750 HTL 90CT GT12 11 DD Low 1 HP Low 1 HP 3 4 1 HP 1200 1750 HTL 100CT GT12 11 DD Low 1 HP Med 1 HP 3 4 1 HP 1200 1750 HTL 120CT GT12 11 DD Low 1 HP High 1 HP 3 4 1 HP 1200 1750 Table A 3 B...

Страница 13: ...0 120 T GT12 11 DD 1 HP 14 0 70 F Low 1631 1592 1548 1506 1452 Table A 5 Belt Drive Blower Characteristics CFM External Static Pressure Inches w c Furnace Model Motor HP Motor FLA T Blower Blower Pull...

Страница 14: ...Rev A 10 27 2005 14 Table A 9 General Dimensions Inches CABINET PLENUM OPENINGS FLUE WIDTH DEPTH HEIGHT SUPPLY RETURN DIAM HEIGHT FILTER PERM SHIP WEIGHT HTL 22 31 58 20 x 20 14 x 22 6 55 16 x 25 x 1...

Страница 15: ...240005126 Rev A 10 27 2005 15 APPENDIX B WIRING DIAGRAMS...

Страница 16: ...ments can be made by moving the fan off and fan on levers on the L6064A Fan Limit dial The fan off setting should stop the blower when the supply air temperature reaches 90 to 100 F The fan on lever i...

Страница 17: ...state Continues to spark for 10 sec a Provides continuous spark after flame is sensed to assure that burner remains lit b Turns on LED diagnostic light c Starts carryover timer i Flame and call for he...

Страница 18: ...olenoid Valve LED Diagnostic Light RETURNS TO IDLE STATE FLAME FLAME FLAME FLAME NO FLAME NO FLAME FLAME LOST FLAME LOST REMAINS IN IDLE STATE R7184 SEQUENCE OF OPERATION LOCKOUT STATE R7184 Shuts off...

Страница 19: ...240005126 Rev A 10 27 2005 19 Figure 3 R7184 Oil Primary Control...

Страница 20: ...ll Resistance Flashes Resistance in Ohms 1 Less than 400 2 Between 400 800 3 Between 800 1600 4 Between 1600 5000 Troubleshooting IMPORTANT Due to the potential hazard of line voltage only a trained e...

Страница 21: ...heat no flame Indicator light is off Go to step 5 Indicator light turns off Eliminate external light source or permanently shield cad cell 4 Shield cad cell from external light Indicator light stays...

Страница 22: ...ne thermostat lead wire Burner starts Trouble in thermostat or limit circuit Check thermostat or limit wiring connections Burner does not start Disconnect the line voltage power and open line switch C...

Страница 23: ...nsure that there is no call for heat Reconnect line voltage power and close line switch Expose new cad cell to bright light such as a flashlight Indicator light is off Go to step 11 Indicator light is...

Страница 24: ...clogged or in some manner defective Check fuel oil lines Replace any compression fittings found with high quality flared fittings Check for any signs of oil leaks Any oil leak is a potential source of...

Страница 25: ...ressure Adjust the oil burner combustion air band and draft regulator to gain the highest practical CO2 or lowest practical O2 content in the flue gases See Burner Set Up Too much smoke Heat exchanger...

Страница 26: ...le Excessive duct losses Check supply air ductwork Seal leaky joints and seams Insulate ductwork if necessary FINAL CHECK OUT ENSURE THAT ALL SAFETY DEVICES AND ELECTRICAL COMPONENTS HAVE BEEN SET FOR...

Страница 27: ...240005126 Rev A 10 27 2005 27...

Страница 28: ...unit 21994 17 Radiator Cleanout Cover 2 per unit 1061A 18 Casing Cleanout Cover 2 per unit 3011325A 19 Filter Frame 16 X 25 18020 20 Filter Frame End Support 5592B2 21 Filter 16 X 25 Permanent 218002...

Страница 29: ...2240001 Blower Pulley 5 X 2240005 Fan Belt 4L Series 2240065 35 Blower Slide Rail 2 Per 18189 32 Heat Exchanger Air Baffle HTL 100C 26236 All parts are the same as listed on the previous pages for Mod...

Страница 30: ...LE Model No Serial No Date Installed Contractor Contact Address Postal Code Telephone No After Hours No If different from Installation Contractor Service Tech Telephone No After Hours No Fuel Supplier...

Страница 31: ...240005126 Rev A 10 27 2005 31 NOTES...

Страница 32: ...Wallaceburg Ontario N8A 5E5 Can Tel 519 627 0791 Fax 519 627 4719 2201 Dwyer Avenue Utica New York 13504 USA Tel 315 797 1310 Fax 315 724 9319 85 Middle Road Dunkirk New York 14048 USA Tel 716 366 55...

Отзывы: