13
Foreword
This stove is a top quality modern heating technology
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmosphere
of an open fire.
Proper installation and correct handling and care are
indispensable for problem-free operation and a long
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced that
you will then derive a great deal of pleasure from this
stove. Please keep these instructions in a safe place
so that you can read through them at the start of each
heating period.
Should you find any transport damage, please report it
to your supplier immediately as otherwise it will not be
possible to correct the damage free of charge.
Stove Tolima PowerSystem II Compact
23/766
Table of Contents
Foreword ................................................................. 13
Technical Data ........................................................ 13
Regulations to be observed .................................. 14
Chimney design ...................................................... 14
Combustion air supply ........................................... 14
Ambient air independent
combustion air connection ........................................ 14
Installing the stove ................................................. 15
Assembly sequence ................................................. 15
Installing the PowerBloc ........................................... 16
Operation ................................................................. 16
Permissible fuels ...................................................... 16
Please note before heating for the first time
............. 17
Igniting ...................................................................... 17
Combustion air slide valve........................................ 17
Regulation of combustion air .................................... 17
Convection air slide valve ......................................... 18
Fire grate .................................................................. 18
Wood storage compartment ..................................... 18
Heating ..................................................................... 18
Heating during the transition period.......................... 19
Cladding .................................................................. 19
Special information ................................................ 19
Cleaning .................................................................. 19
Measuring negative pressure
in the combustion chamber ................................... 20
Replacement parts ................................................. 20
What to do if ...? ...................................................... 20
Technical Data
●
Nominal thermal output ................................. 6,0 kW
●
Room heat output .......................................... 6,3 kW
●
Height to the top edge of connector pipe
with the connection at the top .................... 1360 mm
●
Connection pipe ...................................... Ø 150 mm
●
max. Weight................................................... 325 kg
●
Connection combustion air ...................... Ø 125 mm
●
Operating mode ........................ Intermitting burning
549
1349
221
286
617