Foreword

This stove is a top quality modern heating technology 
product.
A large degree of user comfort and high fuel utilisa-
tion enable it to be used as high quality space heat-
ing, without having to do without the cosy atmosphere 

of an open fire.

Proper installation and correct handling and care are 
indispensable for problem-free operation and a long 
service life. Please therefore observe all the informa-
tion given in these instructions. We are convinced that 
you will then derive a great deal of pleasure from this 
stove. Please keep these instructions in a safe place 
so that you can read through them at the start of each 
heating period.

Should you find any transport damage, please report it 

to your supplier immediately as otherwise it will not be 
possible to correct the damage free of charge.

Stove Tolima PowerSystem II Compact 

23/766

Table of Contents

Foreword ................................................................. 13

Technical Data ........................................................ 13

Regulations to be observed .................................. 14

Chimney design ...................................................... 14

Combustion air supply ........................................... 14

Ambient air independent 
combustion air connection ........................................ 14

Installing the stove ................................................. 15

Assembly sequence ................................................. 15
Installing the PowerBloc ........................................... 16

Operation ................................................................. 16

Permissible fuels ...................................................... 16

Please note before heating for the first time

 ............. 17

Igniting ...................................................................... 17
Combustion air slide valve........................................ 17
Regulation of combustion air .................................... 17
Convection air slide valve ......................................... 18
Fire grate .................................................................. 18
Wood storage compartment ..................................... 18
Heating ..................................................................... 18
Heating during the transition period.......................... 19

Cladding .................................................................. 19

Special information ................................................ 19

Cleaning .................................................................. 19

Measuring negative pressure 
in the combustion chamber ................................... 20

Replacement parts ................................................. 20

What to do if ...? ...................................................... 20

Technical Data

 

Nominal thermal output ................................. 6,0 kW

 

Room heat output .......................................... 6,3 kW

 

Height to the top edge of connector pipe 
with the connection at the top .................... 1360 mm

 

Connection pipe ...................................... Ø 150 mm

 

max. Weight................................................... 325 kg

 

Connection combustion air ...................... Ø 125 mm

 

Operating mode  ........................ Intermitting burning

549

1349

221

286

617

Содержание Tolima PowerSystem II Compact

Страница 1: ...PowerSystem II Compact 23 766 DIN EN 13240 DIN 18897 raumluftunabh ngig DIBt Bauaufsichtliche Zulassung 15a BV G GB D F NL Anleitung Seite 3 12 Instruction Page 13 20 Instructions Page 21 28 Aanwijzi...

Страница 2: ...ng max Heizleistung 1 2 AUF Nennheizleistung mit Scheitholz 1 2 AUF Nennheizleistung mit Holzbrikett ZU Gluthalten Da die Sekund rluft auch zur Scheibensauberkeit beitr gt ist der Bedienhebel beim Abb...

Страница 3: ...Lieferanten zu melden Technische Daten Nennw rmeleistung 6 0 kW Raumw rmeleistung 6 3 kW H he bis Oberkante Anschlussstutzen bei Anschluss oben 1360 mm Anschlussstutzen Ofenrohr 150 mm max Gewicht 32...

Страница 4: ...eratur am Stutzen 305 315 C Mindestf rderdruck bei Nennw rmeleistung 12 12 Pa Verbrennungsluftversorgung Der Kaminofen kann sowohl konventionell raumluftabh ngig als auch raumluftunabh ngig betrie ben...

Страница 5: ...er Position der Feuerraumt r zur Aufstell bzw Seiten oder R ckwand folgende Wandabst nde einzuhalten siehe Prinzipskizze Bei nicht zu sch tzenden Aufstellw nden ist ledig lich ein Mindestabstand f r d...

Страница 6: ...Umwelt Die erh hte Kondensat und Teerbildung kann zur Kamin und Schornsteinversottung f hren Aus dem Diagramm geht hervor dass der Verbrauch bei frisch geschlagenem Holz Heizwert 2 3 kWh kg im Vergle...

Страница 7: ...mt r schlie en damit das Anz ndmaterial gut anbrennen kann Sobald Grundglut vorhanden ist dem W rmebedarf entsprechende Menge Brennstoff nachlegen siehe Kapitel Heizen Achtung Beim Anheizen der Feuers...

Страница 8: ...erschlu ausger stet Es l sst sich durch leichtes dr cken auf den Taster Olsberg Logo ffnen Das Verschlie en erfolgt ebenso durch leichtes dr cken Heizen Nur die Menge Brennstoff auflegen die entspre c...

Страница 9: ...ng anderer als der genann ten Brennstoffe entf llt die Gew hrleistung des Herstellers Der Kaminofen ist nur mit geschlossener Feuer raumt r zu betreiben Keine hei e Asche entnehmen Asche nur in feuers...

Страница 10: ..._ Fabrikationsnummer _________________________ Was ist wenn der Kaminofen nicht richtig zieht Ist der Schornstein oder das Ofenrohr undicht Ist der Schornstein nicht richtig bemessen Ist die Au entemp...

Страница 11: ...Dies gilt jedoch nur bei Einhaltung der auf dem Ger teschild angegebenen Leistungen bei Anschluss an die vorgeschriebene Betriebsspannung und bei Betrieb mit der angegebenen Energieart bzw mit den in...

Страница 12: ...d oder Materialfehler zur ckzuf hren sind Die Man gelbeseitigung erfolgt nach unserer Wahl durch Re paratur oder Lieferung einer mangelfreien Sache in nerhalb eines angemessenen Zeitraumes durch uns o...

Страница 13: ...rge Stove Tolima PowerSystem II Compact 23 766 Table of Contents Foreword 13 Technical Data 13 Regulations to be observed 14 Chimney design 14 Combustion air supply 14 Ambient air independent combusti...

Страница 14: ...pressure at nominal thermal output 12 12 Pa Combustion air supply The stove can be operated conventionally dependent on the ambient air as well as independent of the am bient air It must be guarantee...

Страница 15: ...ing distances from walls need to be observed in accordance with the position of the combustion chamber door to the wall side panel or the back panel see schematic diagram When not dealing with walls t...

Страница 16: ...he in creased condensate and tar formation can lead to fire place and chimney sooting This diagram shows that the consumption rate with freshly felled wood calorific value 2 3 kWh kg is al most twice...

Страница 17: ...o that the kindling material can catch fire Once there is a basic firebed add more fuel accord ing to the heat requirement see chapter Heating Caution When heating up the fireplace difficulties in ign...

Страница 18: ...ow the combus tion chamber is fitted with a magnetic pressure clo sure It can be opened by lightly pressing on the but ton Olsberg logo Likewise it can be closed by light ly pressing Heating Only plac...

Страница 19: ...the nominal heating output or if fuels other than those list ed are used The stove must only be used with the combustion chamber door shut Never remove hot ashes Only store ashes in a fire proof non...

Страница 20: ...23 __________ Fabrication number __________________________ What to do if the stove doesn t draw properly Is the chimney or the stovepipe not tight Has the chimney been incorrectly designed Is the ext...

Страница 21: ...uit du dommage Po le Tolima PowerSystem II Compact 23 766 Table des mati res Pr face 21 Caract ristiques technique 21 Directives respecter 22 Dimensions de la chemin e 22 Alimentation en air de combus...

Страница 22: ...ssion de refoulement minimale puissance nominale 12 12 Pa Alimentation en air de combustion Le po le peut tre utilis aussi bien de mani re conven tionnelle en fonction de l air ambiant et qu ind pen d...

Страница 23: ...mur d installa tion le panneau lat ral ou arri re voir sch ma de principe Si le po le n est pas mont proximit de murs prot ger il convient de respecter uniquement un cart minimal d env 5 cm pour perm...

Страница 24: ...e goudron peut forte ment encrass e le foyer et la chemin e On peut lire sur le diagramme que la consommation en bois fra chement coup valeur thermique 2 3 kWh kg est pratiquement double de celle du b...

Страница 25: ...ble correspondante la chaleur demand e voir chapitre Chauffer Attention Lors de l allumage du foyer si aucun appel d air ne s est encore form dans la chemin e il peut arriver que le bois de chauffage...

Страница 26: ...ici Le casier de stockage du bois situ en dessous de la chambre de combustion est quip d une fermeture magn tique pression Il s ouvre facilement en ap puyant l g rement sur la touche Logo Olsberg La...

Страница 27: ...le ou constante du po le au del du rende ment thermique nominal ainsi qu en cas d emploi d autres combustibles que ceux indiqu s plus haut Il ne faut exploiter le po le que si la porte du foyer est fe...

Страница 28: ...e ici avant l installation Num ro de s rie 23 __________ Num ro de fabrication ________________________ Que faut il faire si le po le ne tire pas bien La chemin e ou le tuyau de chemin e ne sont ils p...

Страница 29: ...steloze schaderegeling mogelijk is Haardkachel Tolima PowerSystem II Compact 23 766 Inhoudsoverzicht Voorwoord 29 Technische gegevens 29 Voorschriften in acht te nemen 30 Schoorsteendimensionering 30...

Страница 30: ...g s Uitlaatgastemperatuur op de aansluitstomp 305 315 C Minimum persdruk bij nominaal warmtevermogen 12 12 Pa Toevoer van verbrandingslucht De haardkachel kan op een conventionele manier af hankelijk...

Страница 31: ...overeenkomstig de positie van de verbrandingsruimtedeur naar de opstel resp zij of achterwand de volgende afstanden tot de wanden worden aangehouden zie tekening Wanneer er bij de opstelling geen wand...

Страница 32: ...gde condensaat en teervorming kan de aanleiding zijn dat de haard en de schoorsteen vol roet en teer geraken Uit het diagram blijkt dat het verbruik bij gekapt hout verwarmingswaarde 2 3 kWh kg in ver...

Страница 33: ...en gloed is ontstaan moet een hoeveel heid brandmateriaal overeenkomstig de warmtebe hoefte worden opgelegd zie hoofdstuk Stoken Attentie Bij het aansteken van de stookplaats dus als zich nog geen tre...

Страница 34: ...brandruimte en is uitgerust met een magneetsluiting Het vak kan geopend worden door licht op de toets met Olsberg logo te drukken Het vak wordt ook ge sloten door de toets licht in te drukken Stoken S...

Страница 35: ...ebruik van andere als de ge noemde brandstoffen vervalt de garantie van de producent De haardkachel mag slechts met gesloten verbran dingsruimtedeur worden gebruikt Geen hete as uitnemen As slechts in...

Страница 36: ...de haardkachel niet goed trekt Is de schoorsteen of de kachelpijp ondicht Is de schoorsteen niet juist gedimensioneerd Is de buitentemperatuur te hoog Is de deur van andere aan de schoorsteen aange s...

Отзывы: