XZAC4219-03 Service
Manual
4-23
This calibration makes it possible to set the distance between the top edge of the document and the first print
line.
This adjustment is activated only if, in the set-up of PR40+ emulation, “N” is selected for the "TOP MARGIN
PR40 LIKE" item.
To carry out this calibration, proceed as follows:
1.
Switch on the printer with the cover open holding down the three console buttons.
2.
Wait for the acoustic signal that indicates access to the calibration and adjustment procedure.
3.
Press the Local button and wait until the end of the machine reset procedure.
4.
Press the Station 1 button. After this phase the three console buttons will be active. With
Station 1, it will be possible reduce the TOF or to increase this with Station 2.
5.
Insert an A4 sheet in the front slot to check the status of the current TOF. This check is made
printing a specific text. If the current TOF is too “high”, printing may be carried out off the
sheet.
6.
Press Station 1 and/or Station 2 to decrease or increase the TOF.
7.
Repeat points 6. and 7. until calibration has been completed.
8.
Press the “Local” button twice to permanently save the TOF and to move automatically to the
next calibration.