4-18
XZAC4219-03
If calibration fails, the faulty photosensor will be indicated by the configurations of the leds. Pressing one the
console button highlights any other faulty photosensors. If calibration is not completed correctly, it will not be
possible to make the other calibrations or measurements. If calibration is successful, insert a sheet of A4
format paper in order to print the calibration values. The parameters to be checked are indicated in the table
below.
1 2
photosensor
Paper No
(mV.)
Paper Yes
(mV.)
Average
val.
(mV.)
Current
(mA.)
photo n. 1 front paper present
XXXX XXXX XXXX XX
photo n. 2 front paper present
XXXX XXXX XXXX XX
photo n. 1 front. paper align.
XXXX XXXX XXXX XX
photo n. 3 front paper align.
XXXX XXXX XXXX XX
photo n. 2 front paper align.
XXXX XXXX XXXX XX
photo n. 4 front paper align.
XXXX XXXX XXXX XX
photo rear paper present
XXXX XXXX 0 0
photo paper top edge
A
XXXX
B
XXXX
3
Parameters to be checked
1) MINIMUM ACCEPTABLE VALUE 4500
2) VALUE
< 1500
3) B – A
2500 MINIMUM ACCEPTABLE VALUE
Make a further check inserting a check format form code 152136J at the two ends and in the center of the slot
with the shorter side parallel to the axis of the photosensors (checking correct functioning of these).
Note:
The parameters indicated above are for guidance and reference purposes in order to know the
functioning range in which the PR2
plus
is positioned with regard to acceptability of the documents.