XZAC4219-03 Service
Manual
4-1
4.
SELF-TEST, SET-UP AND CALIBRATION
4.1
POWER-ON SELF-TEST
The PR2
plus
features a set of diagnostic tests that are activated automatically at power-on.
Any FW or HW faults are highlighted by leds on the console.
POWER-ON DIAGNOSTICS FOR PR2 E – PR2 PLUS
TYPE OF FAULT
LED RDY
LED ST1
LED LOC
LED ST2
Carriage Motor
BLK
BLK
OFF
OFF
Services Motor
BLK
OFF
OFF
OFF
Intro photosensor jam
BLK
OFF
OFF
BLK
Magnetic unit reset
OFF
BLK
OFF
BLK
EEPROM, HW setup
OFF
OFF
BLK
BLK
EEPROM, SW setup
OFF
OFF
BLK
OFF
Photosensor calibration procedure
BLK
BLK
BLK
BLK
Banked RAM diagnostics
OFF
OFF
OFF
BLK
ASIC diagnostics
OFF
BLK
BLK
BLK
Head hot or PTC fault/Flash not written
(automatic DLL)
ON
ON
BLK
ON
At the end of the self-test phase, if no errors have been detected, the printer switches to READY status (ON